Polycom 7000 manual MCUs

Models: 7000

1 437
Download 437 pages 17.13 Kb
Page 368
Image 368

System Management and Maintenance

Alert 3801

<d-cluster>: Cluster <f-cluster>/server <f-server> failover to <b-server> due to

<component> failure: <details of failure>

The cluster from which the alert originated is reporting that a server in a different cluster has failed over to an alternate server because of an internal software component failure. The alert includes details on what component experienced the failure.

This alert is cleared when the condition that caused the alert is resolved.

Use the failure details as a starting point for troubleshooting. If the failure is not hardware or network related, and you are unable to access the server, it may need to be rebooted.

Click the link to go to the Network > DMAs page. See also:

Alerts

Alert 3802

<d-cluster>: Cluster <f-cluster>/server <f-server> restarted due to <component> failure: <details of failure>

The cluster from which the alert originated is reporting that a server in a different cluster has restarted because of an internal component failure. The alert includes details on what component experienced the failure.

Use the failure details as a starting point for troubleshooting. If the failure is not hardware or network related, and you are unable to access the server, it may need to be physically powered off and powered back on.

Click the link to go to the Network > DMAs page. See also:

Alerts

Alert 3803

<d-cluster>: Cluster <f-cluster>/server <f-server> is operating in an impaired state due to

<component> issue: <details of impairment>

The cluster from which the alert originated is reporting that a server in a different cluster has experienced one or more software component issues, and is running in an unhealthy state. The alert includes further details of the impairment of the system.

Use the impairment details as a starting point for troubleshooting. If the impairment is not hardware or network related, and you are unable to access the server, it may need to be rebooted.

Click the link to go to the Network > DMAs page. See also:

Alerts

MCUs

The following alerts provide information on changes in the status of connected MCUs.

Polycom, Inc.

368

Page 368
Image 368