MCU Management
Note: Calculating MCU reliability
After each call, the RealPresence DMA system recalculates the reliability of an MCU as the weighted average of the result for the current call (1 for success, 0 for failure) and the reliability of all previous calls, using this formula:
reliability = (current_call + (weight * previous_reliability)) / (1 + weight)
For example, if weight is 5, previous reliability is 1 (no previous failed calls), and the call is successful, the reliability remains 1:
(1 + (5 *1)) / (1 + 5) = 1
If weight is 5, previous reliability is 1, and the call fails, the reliability becomes 5/6:
(0 + (5 *1)) / (1 + 5) = 5/6
If weight is 5, previous reliability is 5/6, and the call is successful, the reliability becomes 31/36:
(1 + (5 *5/6)) / (1 + 5) = 31/36
If the reliability is ever less than 1, it exponentially approaches 1 as more calls succeed, but it never quite gets there. It very quickly reaches the point where the weight of the past failed call counts less than a single call in progress. But it remains as the tie breaker between completely unused MCUs forever.
See also:
MCU Pool Orders
MCU Selection Process
MCU Pool Order Procedures
MCU Pool Order Procedures
To view the MCU Pool Orders list
»Go to Network > MCU > MCU Pool Orders. The MCU Pool Orders list appears.
To add an MCU Pool Order
1Go to Network > MCU > MCU Pool Orders.
2In the Actions list, click Add.
3In the Add MCU Pool dialog, complete editable fields. All are mandatory. See Add MCU Pool Dialog.
4Click OK.
The new MCU pool order appears in the MCU Pool Orders list. The MCU pools included in the pool order are displayed.
To edit an MCU Pool Order
1Go to Network > MCU > MCU Pool Orders.
2In the MCU Pool Orders list, select the pool order, and in the Actions list, click Edit.
3In the Edit MCU Pool Order dialog, edit the fields as required. See Edit MCU Pool Dialog.
Polycom, Inc. | 151 |