Strata CTX100-S/CTX100 Installation 3

This chapter explains how to install the Strata CTX100-S/CTX100 systems. It includes information on site requirements, wiring diagrams, and step-by-step instructions on how to install the unit(s), the ground wiring, AC power cabling, reserve power (battery backup) cabling, and PCB cabling.

Inspection

1.When the system is received, examine all packages carefully and note any visible damage. If any damage is found, do not open the packages. Contact the delivery carrier immediately and make the proper claims.

2.After unpacking (and before installing), check the system against the packing list and inspect all equipment for damage. If equipment is missing or damaged, contact your supplier immediately.

3.Be sure to retain original packaging materials for re-use when storing or transporting system hardware.

Packaging and Storage

CAUTION! When handling (installing, removing, examining) PCBs, do not touch the back (soldered) side or edge connector. Always hold the PCB by its edges.

When packaging and storing the system, remove PCBs from the system cabinet (the power supply may remain installed in the cabinet for storage and shipment). PCBs should be packaged in their original antistatic bags for protection against electrostatic discharge. Be sure to package equipment in its original shipping containers.

Site Requirements

This section defines the installation site requirements necessary to ensure a proper operating environment for the CTX100. Also included are grounding requirements.

Input Power

The Base Cabinet or the Base and Expansion Cabinet together require an input power source of 120VAC, 60 Hz, 15 amps. Each cabinet plugs into an AC power outlet. Each cabinet requires 1.8 amps AC from the power source or 3.6 amps AC combined. The power supply cord for each cabinet is 4.5 ft. long with a standard three-prong 120VAC plug.

CTX100 Installation

Strata CTX100-S/

 

 

Strata CTX I&M 06/04

3-1

Page 103
Image 103
Toshiba CTX28 manual Strata CTX100-S/CTX100 Installation, CTX100 Installation Strata CTX100-S