Strata CTX670 Installation

Install AC Power Components

Cabinet AC Power Component Description

The table shown below identifies the cabinet parts required to distribute AC power within the Strata CTX670 cabinets.

Table 4-1 Power Cabinet Hardware

Option

Description

 

Cabinet power strip for 120VAC primary power – provides three standard 120VAC/15A outlets

 

(NEMA 5-15R) and nine ft. AC power cord with standard 120VAC/15A plug (NEMA 5-15P). This

 

unit is field installed inside system cabinet side panels. The system can use 12 amps. (max.).

 

See Figures 4-12~4-17.

 

One RPSB2 is required for two or three cabinet systems if the local electric code allows only one

 

AC power cord to be connected to the system.

RPSB2

Note If the local electric code allows only one AC power cord to be connected to the system,

 

208VAC or 240VAC must be used as primary AC power for systems with four or more

 

cabinets.

 

One RPSB2 is required for a three or four cabinet system if the local electric code allows two AC

 

power cords connected to the system.

 

Two RPSB2s are required for a five cabinet system if the local electric code allows two AC

 

power cords connected to the system.

 

 

 

Cabinet power strip for 208VAC or 240VAC primary power. Provides three 240VAC/20A outlets

 

(NEMA 6-20R) and nine ft. AC power cord with a standard 240VAC/20A plug (NEMA 6-20P).

 

This unit is field installed inside system cabinet side panels. The cord is rated at 16 amps.

 

(max.). See Figures 4-14~4-17.

 

One BPSB240 is required for two or three cabinet systems.

 

Two BPSB240s are required for four or five cabinet systems.

BPSB240

Three BPSB240s are required for six or seven cabinet systems.

 

 

Note

 

Local electric codes allow only one AC power cord to be connected to the system when using

 

208VAC or 240VAC as the primary AC power.

 

If using 208VAC as primary power, the plug on the BPSB240 AC power cord

 

(NEMA 6-20P) may have to be changed by a certified electrician depending on local electric

 

codes.

 

 

 

AC208V or AC240VAC nine ft., 10 amps. (max.), power supply cord. This cord must be used

 

when the system is powered by 208VAC or 240VAC. One cord is required for each cabinet

 

power supply and must be ordered separately only if using 208VAC or 240VAC as the system

BACL240

primary AC power.

 

 

Note The cord conforms with a National Electric Code standard plug (NEMA 6-20P) 208VAC/

 

240VAC. The power strip plug that exits the system may have to be changed to a twist-

 

lock type by a certified electrician to conform with local electric codes.

 

 

Installation

Strata CTX670

 

 

Strata CTX I&M 06/04

4-21

Page 147
Image 147
Toshiba CTX28 manual Cabinet AC Power Component Description, Power Cabinet Hardware Option Description