Toshiba CTX28 manual Attach the AC Cable

Models: CTX28

1 495
Download 495 pages 33.26 Kb
Page 198
Image 198

Rack Mount Cabinets

Step 5: Attach the AC Cable

Step 5: Attach the AC Cable

The Rack Mount Cabinet(s) require a single-phase, 50/60 cycles power source of 120, 208, or 240VAC, on a dedicated 20 ampere circuit breaker. 208VAC or 240VAC is required for six or seven cabinet systems.

Toshiba recommends that a dedicated AC service panel be used. AC outlets must be dedicated to rack mount cabinet use, fused, and grounded. Equipment unrelated to the rack mount cabinet(s) must not be connected to the circuit or service panel dedicated to the rack mount cabinet(s).

Note It may not always be possible to power a complete rack mount cabinet system from a single circuit breaker panel. For example, in the case where a cabinet is remotely located.

To avoid accidental turn-off, do not configure the outlet serving the rack mount cabinets with an On/Off switch. AC outlets serving the cabinets must be close enough so that the power cord from the cabinet power supply or power strip can reach the outlet (these power cords are nine ft.).

AC wall outlets for the rack mount cabinets must be on dedicated 20amp breakers. AC outlets must meet National Electrical codes specifications: NEMA 5-20R for 120VAC or NEMA 6-20R for 208VAC/240VAC.

AC power cabling requirements vary, depending on: The method of cabinet installation (i.e., rack, floor or wall mount), AC power source voltage (120VAC, 208VAC or 240VAC) and the number of cabinets.

The cable can be wired from the right front of the cabinet (shown right).

...or

AC Cable

goes through plastic clamp

the cable can be wired from the back (as shown below).

Front View

Back View (with back cover)

AC cable clamp

 

 

 

in back cover

6987

6981

AC Cable is wired

AC Cable Hole

AC cable

to the back

in Back Face

 

CAUTION! Arrange the rest of the AC cables outside the cabinet. Noise from the cables influence electrical components (e.g., motherboard) when the cables are located inside the cabinet.

5-10

Strata CTX I&M 06/04