CTX28 Installation

Installing the CTX28 Cabinet

Step 1: Set Jumpers on the GMAU1A (Motherboard)

The GMAU1A (shown in Figure 1-7) supports up to 6 CO lines with Caller ID (CLID).

ON

SW1

STANDBY

SW1

ON/OFF (Standby)

P5

P6

P8

P7

P4

TB2

CO1

TB3

CO2

CO3

SW400 (3db/0DB)

SW500 (3db/0DB)

SW600 (3db/0DB)

 

 

7113

Figure 1-7 GMAU PCB

 

 

Table 1-4 GMAU Controls, Switches and Indicators

 

 

 

 

Control/Indicator/Connector

Type of Component

Description

 

 

Power Switch:

SW1

2-position slide switch

[STANDBY] = no DC power supply.

[ON] = DC voltage supplied. [ON] activates the

 

 

 

 

reserve power from HPFB-6 battery pack.

 

 

 

SW400

 

 

 

 

 

SW500

2-position slide switch

3dB Pad switch

 

 

 

SW600

 

 

 

 

 

 

 

Power indicator; when SW1 is [ON], turned on.

CD6

LED

Red both AC power and 3Reserve power. SW1

 

 

is [STANDBY], turned off.

 

 

 

TB1

Plate with screw

Grounding for HPFB-6 external battery

 

 

 

TB2

Plate with screw

Grounding for GETS Ethernet card

 

 

 

TB3

Plate with screw

Grounding for CTX28 system, connect to earth

ground

 

 

 

 

 

P1

50-pin Amphenol

DKT, SLT and Power Failure Transfer interface

connector

 

 

 

 

 

P3

44-pin DIN connector

GMAS interface

 

 

 

1-10

Strata CTX I&M 06/04

Page 30
Image 30
Toshiba CTX28 manual Set Jumpers on the GMAU1A Motherboard