MDF PCB Wiring

Station Loop Lengths

Station Loop Lengths

In a single site installation, the Base and optional Expansion Cabinets must be placed within the allowed maximum distance of each other as designated by Table 10-1

Table 10-1 Station Loop Lengths1

 

Maximum line length (24 AWG)

Mode

1 Pair2

2 Pair

 

1 Pair plus

 

 

external power 3

 

 

 

 

DKT3000 or DKT2000-series 4

 

 

 

 

DKT with BVSU or DVSU

 

 

 

 

 

 

 

 

 

DKT with

 

 

 

 

BHEU or HHEU

1000 ft. (303m)

 

 

 

 

 

 

 

DKT with BPCI

 

 

 

 

 

 

 

 

 

 

 

 

DKT with BPCI + BHEU

 

1000 ft. (303m)

 

1000 ft. (303m)

 

 

 

DKT with BVSU + BHEU

 

 

 

 

 

 

or DVSU + HHEU

 

 

 

 

 

 

 

 

 

DKT with DADM3020 or DADM2020

675 ft. (204m)

 

 

 

(1 ADM)2

 

 

 

 

 

 

 

DKT with DADM3020 or DADM2020

500 ft. (151m)

 

 

 

(2 ADMs)2

 

 

 

 

 

 

 

DDSS3060 or DDSS2060

 

 

 

 

 

 

 

 

 

BATI, RATI

1000 ft. (303m)

n/a

 

n/a

 

 

 

 

 

DDCB3

 

1000 ft. (303m)

 

1000 ft. (303m)

 

 

 

 

 

 

Approx. 3000 ft.

 

 

 

 

(909 m) with 150

 

 

 

 

ohm device. 5

 

 

 

Standard telephones, voice mail, AA,

Approx. 9000 ft.

 

 

 

(2727 m) with 150

n/a

 

n/a

etc.

 

ohm device.5

 

 

 

 

 

 

 

 

Approx. 21000 ft.

 

 

 

 

(6363 m) with 150

 

 

 

 

ohm device.5

 

 

 

 

The IP telephone interface is 10Base-T/100Base-TX and requires

 

CAT5/5e/6 twisted pair cabling.

 

IPT1020-SD

The maximum distance between the IP telephone jack and the

ethernet device it connects to is 100 meters (328 ft.). This includes

 

the 3 meter (9.84 ft.) straight-through CAT5 cable (black) supplied

 

with the IP telephone. Ethernet devices include

 

 

BIPU-M2A, BIPU-M1A servers, routers, etc.

 

 

 

 

 

 

1.When the system is powered by backup battery, range may be less as the backup battery is discharged.

2.One-pair wiring must be used with BWDKU and BDKS (see Figure 10-3 on page 10-6). The BWDKU and BDKS do not support two pair wiring.

3.Two-pair wiring or optional telephone power supply is required to achieve maximum range in all cases.

4.BDKS and BWDKU do not provide the power wire pair; an external power supply is required to achieve maximum range (see Figure 10-6 on page 10-9).

5.See manufacturer’s product specifications for exact resistance of device.

10-2

Strata CTX I&M 06/04

Page 374
Image 374
Toshiba CTX28 manual 10-2, Station Loop Lengths1, Mode Pair Pair plus