F1~F4 Battery

Fuses 250VAC/15A

To BBDB

Battery Distribution Box

F3F1

F4F2

F3F1

F4F2

Strata CTX670 Installation

Install Reserve Power

BCCB120 (top view)

3outlets NEMA:5-15R Fused: 250VAC/15A Rated: 125VAC/15A

BCCB240 (top view)

2outlets NEMA:6-20R Not Fused Rated: 250VAC/20A

BATT

BCCB

AC

 

+

-

L

N

Battery Wire Specifications

 

 

 

#10 AWG minimum (2 pairs)

 

 

 

42A max.

 

 

 

 

 

 

5047

Conduit

Holes to 1/2 inch trade size

From

From

reserve

20A dedicated

battery

circuit

WARNING!

BCCB conduit boxes must be installed by a certified electrician.

Figure 4-25 BCCB AC Power and Battery Connections

AC Wire Specifications:

BCCB120 #10 AWG 29A max.

BBCB240 #12 AWG 18A max.

Installation

Strata CTX670

 

 

Notes

When floor mounting the CTX670, the batteries must be installed by a licensed electrician per local electric code using conduit. (See Figure 4-25.)

Batteries should be installed in a customer-supplied commercial battery box or enclosed rack.

Strata CTX I&M 06/04

4-41