MDF PCB Wiring

Station Wiring Diagrams

Digital Telephone DSS and DDCB External Power Connection

BDKU or PDKU

Connector

 

W-BL

26

1

 

BL-W

1

 

2

 

W-O

27

 

3

 

O-W

2

 

4

 

W-GN

28

 

5

 

GN-W

3

 

6

 

W-BR

29

 

7

 

BR-W

4

 

8

 

W-S

30

 

9

 

S-W

5

 

10

 

R-BL

31

 

11

 

BL-R

6

 

12

 

R-O

32

 

13

 

O-R

7

 

14

 

R-GN

33

CONNECTOR

15

GN-R

8

16

 

 

R-BR

34

 

17

 

BR-R

9

 

18

 

R-S

35

 

19

 

S-R

10

AMP

21

BK-BL

36

 

 

 

20

W/MALE

BL-BK

11

24

 

BK-O

37

22

 

23

 

O-BK

12

 

 

CABLE

BK-GN

38

25

GN-BK

13

 

 

26

 

BK-BR

39

 

27

PAIR-

BK-S

40

29

 

BR-BK

14

28

 

 

 

25

S-BK

15

30

 

 

Y-BL

41

 

31

 

BL-Y

16

 

32

 

 

 

Bridging

Clips

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

Station Cabling

 

Jacketed Twisted Pairs

(-)

T1 (Voice/Data)

 

24AWG (1 Pair)

 

 

 

 

(GND)

R1 (Voice/Data)

 

 

 

PT1

(Not Used)

 

 

 

RT2

 

 

 

 

 

 

 

 

T2

 

 

 

 

 

R2

 

DC Output

 

R

GN

PT2

CKT 2

 

 

 

 

 

 

PR2

 

AC/DC External

R1

T1

T3

 

BK

Y

R3

 

Power Source

 

 

 

PT3

CKT 3

 

 

W

BL

PR3

 

 

 

 

AC Input

 

 

 

T4

 

 

 

 

 

 

 

 

 

R4

 

 

 

6 5 4 3 2 1

PT4

CKT 4

To 120VAC Commercial

 

 

PR4

 

2 3 4 5

 

 

Power Outlet

 

 

T5

 

 

TR

 

 

 

 

 

R5

 

 

 

 

2-Pair

PT5

CKT 5

 

 

 

 

 

 

Modular Cord

PR5

 

RJ11

 

Required

T6

 

 

 

 

 

 

 

 

R6

 

 

 

 

 

PT6

CKT 6

 

 

 

 

PR6

 

 

 

 

 

T7

 

(-)

GND

 

 

R7

 

 

 

 

T

R

 

 

PT7

CKT 7

 

 

 

 

 

 

PR7

 

 

 

 

 

T8

 

 

 

 

 

R8

 

 

 

 

 

PT8

CKT 8

 

 

 

 

PR8

 

 

 

 

 

MDF PCB

PT/PR power wires are not available on the BDKS or BWDKU.

AC/DC External Power Source Specifications:

AC IN: 120VAC ± 10%

DC OUT: 24VDC ± 10%

160 MA (Min.) DC Current

200 MV P-P (Max) AC Ripple On DC Output

AC/DC power supplies that meet the above requirements are available from most telephone equipment supply houses.

Digital Telephone

(with or w/out BPCI-DI, ADM) or...

DDSS, DDCB, BATI

External Power Straps:

If the external power is installed, cut the external power straps located inside the digital telephone DDSS, DDCB.

See Table 10-1 on page 10-2for external power

Wiring

5665

Figure 10-6 Digital Telephone DSS and DDCB External Power Connection

Strata CTX I&M 06/04

10-9

Page 381
Image 381
Toshiba CTX28 manual Digital Telephone DSS and Ddcb External Power Connection, 10-9, Mdf Pcb