T1

RDTU3 - T1 Interface Unit

RDTU3 - T1 Interface Unit

System:

CTX100 & 670

Circuits per PCB: 8, 16, 24 channels per PCB

Interfaces with: Ground / Loop start CO lines DID or TIE lines (Wink or Immediate)

Older Version(s): RDTU1, RDTU2

The RDTU3A has an RS-232C port to trace data that is transmitted between the CTX system CPU and the RDTU3A. This PCB also enables T1 line alarm data to be monitored.

T1 Framing: D4 (SF) or ESF

Line cording: AMI with ZCS or B8ZS

Digital PAD: Transmit side +3dB to -15dB. Receive side +3dB to -15dB (software controlled)

Table 8-1 RDTU3 Controls, Indicators, and Connectors

Control/Indicator/

Type of Component

Description

Connector

 

 

SW4~SW6 Equalizer Setting

Jumper switches

Sets the line length between RDTU and CSUs

Switch

or other T1 (see also Table 8-6).

 

 

 

 

 

 

Used for Self Test and CSU Test or for non-

SW8, SW9

Jumper switches

loop back normal operation (see also Table

 

 

8-5).

 

 

 

SW10

3-terminal jumper plug

See Table 8-3.

 

 

 

IC19

External ROM upgrade

Provides external ROM option (see Table 8-3).

 

 

 

Status/Alarm LEDs

FSYNC

MFSYNC

BALM/AIS

YALM/RAI

LOS

BSY

PSYNC

SSYNC

RJ-45

8-pin Modular

Network/CSU

Interface Jack

FSYNC

MFSYNC

BALM/AIS

YALM/RAI

LOS

BSY

PSYNC

SSYNC

J2

 

ON

 

ON

R28

 

R28

 

EQ

 

EQ

 

SW4

OFF

SW5

OFF

ON

 

 

 

SW8

 

LB

 

OFF

 

 

 

ON

 

 

 

SW9

 

LB

 

OFF

 

 

 

 

ON

R28

 

EQ

 

SW6

OFF

 

ROM

 

SW10

 

CPU

IC19

 

ON

R28

 

EQ

 

SW4

OFF

ON

 

SW8

 

OFF

 

 

ON

R28

 

EQ

 

SW5

OFF

LB

 

ON

R28

 

EQ

 

SW6

OFF

 

ROM

 

SW10

 

CPU

RS-232C

 

 

 

 

 

 

J1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector for

 

 

 

 

 

 

 

 

 

 

 

MONITOR

 

Call Data

 

 

 

 

 

 

Monitor (RJ-12)

 

 

 

 

 

 

RDTU3A

Backplane

6351 Connector

ON

 

SW9

OFF

LB

Figure 8-1 RDTU3 PCB

8-2

Strata CTX I&M 06/04

Page 310
Image 310
Toshiba CTX28 manual RDTU3 T1 Interface Unit, RDTU3 PCB