Toshiba CTX28 Astu Standard Telephone Interface Unit CTX100 only, Astu Installation, ASTU1 Wiring

Models: CTX28

1 495
Download 495 pages 33.26 Kb
Page 228
Image 228

PCB Installation

ASTU – Standard Telephone Interface Unit (CTX100 only)

ASTU – Standard Telephone Interface Unit (CTX100 only)

Circuits per PCB: two standard telephone circuits

maximum number of ringers per circuit is three

Interfaces with: standard telephones (no message waiting) other single-line devices

alternate BGM source FAX machine

voice mail devices

Older Version(s): none

The ASTU works with the CTX100 Base system with R1.3 and higher software. It provides two standard telephone ports and connects to a unique slot on the side of the CTX100. It does not occupy one of the universal slots.

ASTU Installation

1.Turn the power to the CTX100 off (press the DC power switch) and unplug the system.

2.Remove the front and left-side covers from the CTX100.

3.Refer to Figure 6-1and Table 6-2. Make sure the SW2 switch is in the “Mu law” position for the U.S. and Canada.

4.Align the holes on the ASTU with the white plastic posts on the left side of the CTX100 Base Cabinet. Firmly press the ASTU onto the posts to attach it to the CTX100. Make sure that you can still reach all attached cables and wires.

5.Slip the spade of the FG1 (green wire) under the grounding screw on the CTX100 and tighten the screw.

6.From the CTX100, locate the multi-colored five wire cable (white connector) and plug it into the P1 connector on the ASTU.

7.On the ASTU, locate the 10-wire P2 connector cable and plug it into the front of the ACTU processor PCB on the CTX100 (see Figure 6-2). Press firmly so that both black flip-locks snap shut. (To remove, flip up the front and back locks.)

8.Connect the standard telephone(s) or devices to J1 and J2 on the ASTU.

9.Plug in the CTX100 power and turn on the DC power switch in the front of the CTX100. If everything seems to be working, re-attach the outside covers.

10.Power down and power up the CTX100 and the system will automatically recognize the ASTU in virtual slot 09. Otherwise, you can use CTX WinAdmin R1.3 or later to assign the ASTU in the 0109 position.

ASTU1 Wiring

1.300 ohms loop resistance max., including the telephone or other devices DC off-hook resistance.

2.ASTU requires secondary protectors with standard voltage for outside wiring. See Table 6-1for electrical characteristics.

6-4

Strata CTX I&M 06/04

Page 228
Image 228
Toshiba CTX28 manual Astu Standard Telephone Interface Unit CTX100 only, Astu Installation, ASTU1 Wiring