Toshiba CTX28 manual CTX100 Analog Tie, did and/or Ground Start Lines, Strata CTX Configuration

Models: CTX28

1 495
Download 495 pages 33.26 Kb
Page 81
Image 81

 

 

 

 

Strata CTX Configuration

 

 

 

CTX100 Max. Capacity Configuration Examples

Table 2-42 CTX100 Base: 16 stations, 12 Tie, DID and/or Ground Start Lines

 

 

 

 

 

S101

S102

S103

S104

 

BDKU/

RxxU

RxxU1

RxxU

 

BDKS

 

 

 

 

 

 

 

 

 

 

16 DKTs

4 lines

4 lines

4 lines

 

 

 

 

 

 

1.RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.

Table 2-43 CTX100 Base: 0 stations, 16 Tie, DID and/or Ground Start Lines

S101

S102

S103

S104

RxxU1

RxxU

RxxU

RxxU

4 lines

4 lines

4 lines

4 lines

 

 

 

 

1.RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.

CTX100: Analog Tie, DID and/or Ground Start Lines

Table 2-44 CTX100 Base and Expansion Cabinet with Analog Tie, DID and/or Ground Start Lines

8 Universal Slots

72 Stations (Max.)

32 CO lines (Max.)

80 Stations + Analog Tie, DID and/or Ground Start Lines combined

(Max.)

Table No.

Stations

Analog Tie, DID, and/or Ground Start Lines

 

 

 

2-45

72

12 lines (4 Tie/DID max.)

 

 

 

2-46

64

16 lines (8 Tie/DID max.)

 

 

 

2-47

56

16 lines (12 Tie/DID max.)

 

 

 

2-48

48

16 lines any type

 

 

 

2-49

48

20 lines (16 Tie/DID max.)

 

 

 

2-50

32

24 lines any type

 

 

 

2-51

16

28 lines any type

 

 

 

Strata CTX Configuration

Table 2-45 CTX100 Base & Expansion: 72 stations, 4 Tie or DID and 8 Ground Start Lines

S101

S102

S103

S104

S105

S106

S107

S108

BDKU/

BDKU/

ADKU

RGLU2

BDKU/

BDKU/

RxxU1

RGLU2

BDKS

BDKS

BDKS

BDKS

 

 

 

 

 

 

 

 

 

 

 

 

16 DKTs

16 DKTs

8 DKTs

4 lines

16 DKTs

16 DKTs

4 lines

4 lines

 

 

 

 

 

 

 

 

1.RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.

2.RGLU can not be substituted with REMU or RDDU because of cabinet power factor.

Table 2-46 CTX100 Base & Expansion: 64 stations, 8 tie or DID and 8 Ground Start Lines

S101

S102

S103

S104

S105

S106

S107

S108

BDKU/

BDKU/

RxxU

RGLU2

BDKU/

BDKU/

RxxU1

RGLU2

BDKS

BDKS

BDKS

BDKS

 

 

 

 

 

 

 

 

 

 

 

 

16 DKTs

16 DKTs

4 lines

4 lines

16 DKTs

16 DKTs

4 lines

4 lines

 

 

 

 

 

 

 

 

1.RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.

2.RGLU can not be substituted with REMU or RDDU because of cabinet power factor.

Strata CTX I&M 06/04

2-35

Page 81
Image 81
Toshiba CTX28 manual CTX100 Analog Tie, did and/or Ground Start Lines, Strata CTX Configuration