CTX28 Installation

Installing the CTX28 Cabinet

Note The CTX28 KSU does not provide a battery charger, the HPFB-6 contains built-in batteries and a battery charger; therefore, do not connect any other type of batteries to the CTX28.

To P10 Connector (see Fig. 1-2)

2“

#10 AWG HPFB FG Wire to TB1

(see Fig. 1-2)

HPFB Unit:

Reserve Power Battery

and Charger (optional)

CTX28 Installation

7253

From Second HPFB (optional)

2“

2“

2“

Figure 1-14 HPFB-6 Reserve Power Installation

Step 9: Install Wiring

1.Refer to Figure 1-15for the following steps. Loosen the screw on the Amphenol clamp and remove the clamp. Plug in the 25-pair Amphenol connector and replace the clamp to hold the Amphenol connector in place.

2.Connect all other PCB wiring (e.g., modular CO line cords, LAN cable, etc.). Slide the shorter tie-wrap through the holder. Then fasten wiring to the unit with the tie wrap that comes with the Base KSU.

3.Connect the end of the AC adapter cable to the GMAS PCB as shown in Figures 1-15and 1-16.

4.Connect the other end of the GETS (100Base TX) LAN cable to the LAN connected to the CTX WinAdmin PC.

5.Plug the AC adapter into a power strip connected to an power outlet.

6.Put the On/Standby switch into “On” position. The DC LED should light green. The CTX28 is now ready to program.

WARNING! Do not smoke near batteries. Avoid creating any electrical sparks near batteries.

Strata CTX I&M 06/04