Station Apparatus

3000-series Telephone Option PCBs

Some of the option PCBs are compatible, meaning that more than one option can be added to a telephone. The following table shows which options are compatible.

Table 11-3 Station Option Interface PCB Compatibility

Item

BPCI

BHEU/

BVSU

ADM

HHEU

 

 

 

 

BPCI

 

X

NC

NC

BHEU/HHEU

X

 

X

X

BVSU

NC

X

 

NC

ADM

NC

X

NC

 

 

 

 

 

 

X = Compatible, can be used together in the same telephone.

NC = Not compatible, cannot be used together in the same telephone.

Option PCBs must be compatible with type of telephone (i.e., 3000- or 2000-series) they are installed in (see Table 11-4for compatibility).

Table 11-4 DKT3000 and DKT2000 Component Compatibility

Item

2000-series DKT

3000-series DKT

Add-on Modules

DADM2020 only

DADM3020, DADM3120

 

 

 

Desktop Computer

 

 

Telephony Interface

n/a

BPCI only

(CTI)

 

 

 

 

 

Speaker OCA

BVSU or DVSU

BVSU only

 

 

 

Tilt Stands

BTSD for DKT

BTSD for DKT and BTSA

for DKT with ADM(s)

 

 

 

 

 

Item

2000- and 3000-series DKTs

Headset Interface

HHEU2 and BHEU

 

 

 

External Ringer

HHEU2/HESB and BHEU/HESB

 

 

 

DKT2104 and DKT2004. When these cordless

Cordless Telephones

telephones are connected to a DKT3000, the

DKT3000 must be placed in DKT2000 mode (see

 

 

“DKT2000 Mode On/Off” on page 11-19).

 

 

 

11-4

Strata CTX I&M 06/04

Page 402
Image 402
Toshiba CTX28 manual 11-4, Bpci Bheu Bvsu ADM Hheu BHEU/HHEU, DKT3000 and DKT2000 Component Compatibility Series DKT, Cti