Toshiba CTX28 manual Rcms LEDs, LED Indications Normal Operation Status, Nb Led Cb Led

Models: CTX28

1 495
Download 495 pages 33.26 Kb
Page 265
Image 265

PCB Installation

RMCU/RCMS – E911 CAMA Trunk Direct Interface

RCMS LEDs

Customer Busy (CB) LEDs – The RMCU firmware controls this LED synchronizing with off-hook status inside switch.

Network Busy (NB) LEDs – RMCU hardware controls this LED synchronizing with the supply of voltage from the carrier.

Table 6-20 LED Indications (Normal Operation)

 

Status

NB LED

CB LED

 

(Network Busy)

(Customer Busy)

 

 

1

No network connection.

On

Off

RMCU is in stand-by mode.

 

 

 

 

 

 

 

2

Network connected.

Off1

Off

RMCU is in stand-by mode.

 

 

 

 

 

 

 

 

Network is in stand-by mode and the RMCU

 

 

3

is off hook.

Off

On

Network is connected and the RMCU MF

 

 

 

 

sending dial tone.

 

 

 

 

 

 

4

Network is seizing and the RMCU is off-

Flashing

On

hook.

 

 

 

 

 

 

 

 

Network is connecting, before ANI is sent,

 

 

5

and the RMCU is sending.

On

On

Network is connecting and the RMCU is

 

 

 

 

communicating.

 

 

 

 

 

 

 

 

On then Off

 

6

Network is disconnecting first and then the

NB is turned off, then

On then Off

RMCU disconnects.

approx. 400 msec

 

 

 

 

after CB is turned off.

 

 

 

 

 

 

 

On then Off

 

7

RMCU is disconnecting first and then the

NB is turned off

On then Off

network disconnects.

within 700 msec after

 

 

 

 

CB is turned off.

 

 

 

 

 

1.If the NB LED stays On, even if the modular connector of the network is connected, check the following:

Tip and Ring could be reversed.

Network could be busy.

PCB Installation

Strata CTX I&M 06/04

6-41

Page 265
Image 265
Toshiba CTX28 manual Rcms LEDs, LED Indications Normal Operation Status, Nb Led Cb Led, Network Busy Customer Busy