Strata CTX Configuration

Primary/Reserve Power Cabinet Hardware

Table 2-66 CTX670 Power Cabinet Hardware

Option

Description

 

 

 

Strata CTX670 cabinet power supply must be ordered for each cabinet. Operates with 120VAC,

 

208VAC, or 240VAC connected as the system’s primary AC power source. It automatically

 

detects and adjusts to the type of primary AC power that is connected. The power supply is

BPSU672

included with each cabinet ordered but must be installed in the field.

 

Standard 9 ft. AC power cords with AC120VAC/15A plugs are provided with Strata CTX Base or

 

Expansion cabinets. When AC208V or AC240V power is used, a special AC cord, BACL240, is

 

required for each cabinet power supply and must be ordered separately.

 

 

 

Cabinet power strip for 120VAC primary power – provides three standard 120VAC/15A outlets

 

(NEMA5-15R) and nine ft. AC power cord with standard 120VAC/15A plug (NEMA5-15P). This

 

unit is field installed inside system cabinet side panels. The system can use 12 amps. (max.).

 

One RPSB2 is required for two cabinet systems if the local electric code allows only one AC

 

power cord to be connected to the system.

RPSB2

If the local electric code allows only one AC power cord to be connected to the system, 208VAC

 

or 240VAC must be used as primary AC power for systems with four or more cabinets.

 

One RPSB2 is required for a three or four cabinet system if the local electric code allows two AC

 

power cords connected to the system.

 

Two RPSB2s are required for a five cabinet system if the local electric code allows two AC

 

power cords connected to the system.

 

 

 

Cabinet power strip for 208VAC or 240VAC primary power - provides three 240VAC/20A outlets

 

(NEMA 6-20R) and 9ft. AC power cord with a standard 240VAC/20A plug (NEMA 6-20P). This

 

unit is field installed inside system cabinet side panels. The system can use 16 amps. (max.).

 

One BPSB240 is required for two or three cabinet systems.

 

Two BPSB240s are required for four or five cabinet systems.

BPSB240

 

 

Local electric codes allow only one AC power cord to be connected to the system when using

 

208VAC or 240VAC as the primary AC power.

 

BPSB240 conforms to the National Electric Code standards. If using 208VAC as primary power,

 

the plug on the BPSB240 AC power cord that exits the cabinet (NEMA 6-20P) may have to be

 

changed to a twist-lock type by a certified electrician to conform with local electric codes.

 

 

 

AC208V or AC240VAC nine ft. power supply cord. The cord is rated at 10 amps. (max.) and

 

must be used when the system is powered by 208VAC or 240VAC. One cord is required for

 

each cabinet power supply and must be ordered separately only if using 208VAC or 240VAC as

 

the system primary AC power.

BACL240

The cord is equipped with a 250VAC/20A plug (NEMA 6-20P) which is standard for 240VAC. If

 

using 208VAC as the system primary power this cord may have to be changed by a certified

 

electrician for one or two cabinet installations. If using three or more cabinets, a BPSB240

 

power strip is required and the power strip plug may have to be changed by a certified

 

electrician depending on local electric codes.

 

 

 

A three-meter long battery cable is used to connect reserve power batteries to the system

 

power supply when the system has less than three cabinets. One reserve power cable is

PBTC-3M

required for each cabinet in a one or two cabinet system (wall or floor mount). The cable

 

connects the Strata CTX670 cabinet power supply directly to the battery terminals (a BBDB is

 

not required).

 

 