ISDN Interfaces

RBUU/RBUS Interface Unit

Table 7-14 Four-Pair with RJ45 Demarc Jack Coding

Conductor

 

Color

 

T56A Pin

 

T56B Pin

Use

 

Pair 1

 

 

White-Blue

 

5

 

5

 

Line 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

 

4

 

4

 

Line 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair 2

 

 

White-Orange

 

3

 

1

 

Line 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orange

 

6

 

2

 

Line 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair3

 

 

White-Green

 

1

 

3

 

PS3 plus power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

2

 

6

 

PS3 minus power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair 4

 

 

White-Brown

 

7

 

7

 

PS2 plus power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brown

 

8

 

8

 

PS2 minus power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 7-15 Three-Pair with RJ11 Demarc Coding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conductor

 

Color

 

 

Pin

 

Use

 

 

Pair 1

 

White-Blue

 

 

4

 

Line 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

3

 

Line 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair 2

 

White-Orange

 

 

2

 

Line 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orange

 

 

5

 

Line 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pair3

 

White-Green

 

 

1

 

Line 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

6

 

Line 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

PS2 and PS3 are not used with the Strata CTX BRI-U interface PCBs.

Check with the BRI circuit supplier to determine the pin out of the demarc jacks because some jacks may be wired with two or three BRI-U line circuits each jack.

Station-Side Cabling

The ISDN BRI U-interface circuits are two-wire on the Strata CTX station-side.

The maximum distance between the Strata CTX ISDN BRI-U, station-side circuit (LT) and the U-type Terminal Equipment or Terminal Adapter is 18kft.

The house wiring from the Strata CTX BRI circuit to the wall jack should be made with CAT3~ CAT5 twisted pair wire.

Each station-side BRI circuit requires a ferrite core as shown in Figure 7-16 on page 7-23.

The flat satin telephone cord that connects from the wall jacks to ISDN terminal equipment should be no longer than 33 feet.

BRI station-side cables should not be shielded.

Polarity of the U interface pair is not critical.

The U interface pair should go directly from the Strata CTX interface PCB to the U-type TE1 or TA with no bridge taps or loading coils to different locations.

The pin-out of the RBUU/RBUS BRI jack is shown in Figure 7-25:

Call Monitor Jack Cabling

The pin-out for the BRI-U interface call monitor jack is provided in Figure 7-32of this chapter.

7-32

Strata CTX I&M 06/04

Page 298