CTX28 Installation

Site Requirements

Site Requirements

This section defines the installation site requirements necessary to ensure a proper operating environment for the CTX28. Also included are grounding requirements.

Input Power

The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 1.5 amps. The AC outlet is recommended to be dedicated and unswitched. (See “AC Power and Grounding Requirements” on page 1-4.)

This eliminates interference from branch circuit motor noise or the like, and to prevent accidental power-off. To avoid accidental power turn-off, Toshiba recommends that you do not use an On/Off wall switch on this dedicated AC circuit.

For the Strata CTX28, a reserve power source (HPFB-6) may be connected to the system to serve as a power failure backup (See Step 8 on page 1-18).

Clearance and Location

The minimum clearance requirements for the Strata CTX28 Base cabinet is shown in Figure 1-1. Refer to Figure 1-5 on page 1-7for CTX28 KSU mounting instructions.

Consider the following conditions when selecting a location for the KSU(s):

The location must be:

Dry and clean

Well ventilated

Well illuminated

Easily accessible The location must not be:

Subject to extreme heat or cold

Subject to corrosive fumes, dust, or other airborne contaminants

Subject to excessive vibration

Next to television, radio, office automation, or high frequency equipment

If reserve power (HPFB-6) is to be installed for the Strata CTX28, the batteries will require a well-ventilated location close to the CHSU28A.

Top View

3.5" Wall

3 Feet

Front View

2"

 

 

12.25"

 

2"

 

 

 

 

 

 

 

 

 

 

 

2"

 

 

 

 

 

 

CTX28

Base KSU

18"

7062

2"

 

 

Figure 1-1 CTX28 Base KSU Clearance

Requirements

1-2

Strata CTX I&M 06/04

Page 22
Image 22
Toshiba CTX28 manual Site Requirements, Input Power, Clearance and Location