Toshiba CTX28 manual RDTU1 & 2 T1 Interface Unit, RDTU1 & 2 Installation, Ctx

Models: CTX28

1 495
Download 495 pages 33.26 Kb
Page 323
Image 323

T1

RDTU1 & 2 - T1 Interface Unit

RDTU1 & 2 - T1 Interface Unit

Circuits per PCB: 8, 16, or 24 channels

Interfaces with: ground start CO lines loop start CO lines DID or Tie lines

Older Version(s): none

RDTU is configured for Tie or DID lines and an RRCS must be installed for DTMF operation. LEDs on the RDTU show a continuous status of RDTU operation. The Strata CTX can support up to eight RDTU2 or RPTU2 PCBs total.

RDTU controls and interface connectors are shown in Figure 8-7and described in Table 8-12.

The RDTU requires installation of a customer-provided Channel Service Unit (CSU). Refer to “CSU Installation” on page 8-19for CSU installation.

Testing procedures (local loop back and remote loop back) are in “Loop Back Testing” on page 8-19.

SW1 Equalizer Switch and Loop Back Jumpers (Internal Option)

The distance between the Strata CTX cabinets and the CSU (or other customer premise T1 circuit) determines the setting of the SW1 Equalizer Switch. The SW1 switch consists of a bank of smaller switches, S1~S7.

Set the SW1 switch per Table 8-11.

Table 8-11 RDTU1 & 2 Equalizer Switch and Loop Back Jumpers

Mode

Feet from Strata

S1

S2

S3

S4

S5

S6

S7

S8

CTX

 

 

 

 

 

 

 

 

 

Short

0~150

On

Off

Off

Off

Off

Off

Off

N/A

 

 

 

 

 

 

 

 

 

 

Medium

151~450

Off

On

Off

On

Off

On

Off

N/A

 

 

 

 

 

 

 

 

 

 

Long

450~655

Off

Off

On

Off

On

Off

On

N/A

 

 

 

 

 

 

 

 

 

 

Note The maximum distance between the RDTU and the CSU or other T1 circuits can not be more than 655 feet (see “RDTU to PBX T1 (Separated More Than 655 ft.)” on page 8-6).

RDTU1 & 2 Installation

1.Set jumper wire plugs P1 (LB), P2, P3, and P4 to the Off position. See “Loop Back Testing” on page 8-19for loop back testing procedures.

See “SW1 Equalizer Switch and Loop Back Jumpers (Internal Option)” on page 8-15for the appropriate SW1 equalizer switch setting.

2.Insert the RDTU (component side facing right) into the appropriate slot and apply firm, even pressure to ensure proper mating of connectors. (See “Worksheet 6: Strata CTX670 Cabinet Slots” on page 2-37for RDTU slot assignment recommendations.) (See Figure 8-6.)

T1

Strata CTX I&M 06/04

8-15

Page 323
Image 323
Toshiba CTX28 manual RDTU1 & 2 T1 Interface Unit, SW1 Equalizer Switch and Loop Back Jumpers Internal Option, Ctx