T1

RDTU3A Call Data Information

Table 8-8 RDTU3 Indications (continued)

 

Indication

Indication

Timing

 

 

Type

 

 

 

 

 

 

TLCS-900

 

 

 

 

stack pointer

 

Watch Dog Timer

 

 

and program

SP = xxxxxxh PC = yyyyyyh

 

 

reset will occur.

 

 

counter

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

CH.xx DTyy DRzz DDT1/0

Changing of yy or zz

 

 

 

xx = channel number, from 0 to 23

 

 

 

or DDT will occur.

 

 

Data-HWY

yy = DHin data code (RDTU3A to RCTU) See Table 8-9.

 

 

Each voice channel’s

 

 

code

zz = DHout data code (RCTU to RDTU3A) See Table

 

 

DHin and DHout data

 

 

 

 

 

 

8-10.

 

 

 

will be indicated.

 

 

 

DDT1 means Don’t Disturb Time. DDT0 is normal time.

 

 

 

 

 

 

 

 

 

 

Table 8-9 DT (DHin) Data Code

 

 

 

 

 

 

 

 

Data (Hex)

Meaning

 

 

 

00

No error T1 unit operation is good.

 

 

 

 

 

 

 

 

01

Receive B-bit fall down (Ringing signal for CO Loop/Ground)

 

 

 

 

 

 

 

 

02

Receive B-bit rise up (Ringing signals for CO Loop/Ground)

 

 

 

 

 

 

 

 

09

Receive Off-Hook from line

 

 

 

 

 

 

 

 

0A

Receive On-Hook from line

 

 

 

 

 

 

 

 

11

Receive DP Dial 1

 

 

 

 

 

 

 

 

12

Receive DP Dial 2

 

 

 

 

 

 

 

 

13

Receive DP Dial 3

 

 

 

 

 

 

 

 

14

Receive DP Dial 4

 

 

 

 

 

 

 

 

15

Receive DP Dial 5

 

 

 

 

 

 

 

 

16

Receive DP Dial 6

 

 

 

 

 

 

 

 

17

Receive DP Dial 7

 

 

 

 

 

 

 

 

18

Receive DP Dial 8

 

 

 

 

 

 

 

 

19

Receive DP Dial 9

 

 

 

 

 

 

 

 

1A

Receive DP Dial 0

 

 

 

 

 

 

 

 

21

Receive A-bit rise up (Idle signal for CO Ground)

 

 

 

 

 

 

 

 

22

Receive A-bit fall down (Seizer signal for CO Ground)

 

 

 

 

 

 

 

 

23

Receive answer from line

 

 

 

 

 

 

 

 

40

No error

 

 

 

 

 

 

 

 

41

Frame-bit error

 

 

 

 

 

 

 

 

42

CRC error

 

 

 

 

 

 

 

 

43

Frame-bit error and CRC error

 

 

 

 

 

 

 

 

44

Slip error

 

 

 

 

 

 

 

 

45

Frame-bit error and Slip error

 

 

 

 

 

 

 

 

46

CRC error and Slip error

 

 

 

 

 

 

 

 

47

Frame-bit error and CRC error and Slip error

 

 

 

 

 

 

 

8-12

Strata CTX I&M 06/04

Page 320
Image 320
Toshiba CTX28 manual DT DHin Data Code Data Hex Meaning