ISDN Interfaces

BPTU Installation

Table 7-1 SW10 Internal or External ROM Setting

Mode

SW10

Note

 

 

When there is an internal ROM on the CPU (TMP93PW46), BPTUA

Internal ROM

 

operates with the SW10.

CPU

Use this mode when IC19 is not on PCB.

(Default mode)

 

If the SW10 is in CPU position, BPTUA is operating with the internal

 

 

 

 

ROM regardless of IC19 existence.

 

 

 

External ROM

 

BPTUA is operating with the external ROM (IC19).

ROM

Use this mode only when IC19 is on PCB.

(Upgrade)

 

If the SW10 is in ROM position without IC19, the BPTUA will not work.

 

 

 

 

 

BPTU Self Test

1.Remove the RJ45 network cable to perform the Self Test.

2.Remove the BPTU and set the SW8 and SW9 switches to On (see Table 7-2).

3.Insert BPTU back into the same slot that it was in. If all LEDS turn Off except PSYNCH or SSYNCH, the PCB has passed the self test.

4.After self check passes, put the switches back into position for normal operation (both Off) and insert the BPTU PCB back into the appropriate slot.

5.Plug the RJ45 network cable back in.

Note Do not use the BPTU as a clock extraction unit while in Self Test mode.

Table 7-2 SW8, SW9 BPTUA Self and CSU Test

Mode

SW8 and

Notes

SW9

 

 

BPTUA self test

Both On

With both SW8 and SW9 On, all LEDS turn Off. If there is

more than one BPTU, these LEDs will not flash.

 

 

 

 

 

Normal operation (non-loop

Both Off

 

back)

 

 

 

 

 

 

BPTU Cable Length Equalizer Switches

The distance between the Strata CTX, BPTU and CSU or BPTU to other Customer Premise Equipment (CPE) T1 may vary (0~655 ft.) as shown. (See “BPTU Cabling” on page 7-7.) The BPTU interface transmitter must be equalized and its impedance must be matched to the cable length connecting the BPTU to the CSU or other CPE, T1 (see Table 7-3).

Table 7-3 BPTU Equalizer Setting Switch

Mode

Feet from CTX

SW4

SW5

SW6

Short

0 to 133 feet

Off

Off

Off

 

 

 

 

 

Semi-short

133 to 266 feet

On

Off

Off

 

 

 

 

 

Medium

266 to 399 feet

Off

On

Off

 

 

 

 

 

Semi-long

399 to 533 feet

On

On

Off

 

 

 

 

 

Long

533 to 655 feet

X

X

On

 

 

 

 

 

X = Doesn’t matter.

7-6

Strata CTX I&M 06/04

Page 272
Image 272
Toshiba CTX28 manual Bptu Self Test, Bptu Cable Length Equalizer Switches, SW4 SW5 SW6