Strata CTX100-S/CTX100 Installation

Installing the CTX100 Cabinet

Step 18: Install Other PCBs into the Cabinet(s)

1.Each PCB must be configured for the applicable hardware options prior to installation of the PCB to the CTX100 cabinets.

Configuration instructions for individual PCBs are in Chapter 6 – PCB Installation and Chapter 10 – MDF PCB Wiring. Configuration instructions for external hardware options are provided in Chapter 12 – Peripheral Installation.

2.Use the PCB placement guide in “Worksheet 5: Strata CTX100 Cabinet Slots” on page 2-26to determine which PCB slot can be used for each PCB type.

3.Slide the PCB Slot Locking Bar to the right, then insert each of the PCBs; push the PCBs firmly toward the motherboard, making sure that the connectors are secured (see Figure 3-19). Lightly tug on each PCB to make sure that it’s installed securely.

4.After all the PCBs are installed, slide the PCB Slot Locking Bar to the left to lock the PCBs into place.

5.Configure the PCBs for software options through programming. Refer to the Strata CTX Programming Manual for more detailed programming instructions.

Note The Base and Expansion cabinets

6005

have four universal PCB slots

Figure 3-19 PCB Slot Locking Bar

each which can accept the same

 

universal PCBs as the CTX670.

 

CTX100-only components are

 

shown in Table 3-2.

 

PCB Slot Locking Bar

Table 3-2 CTX100 Cabinet and Processor Components

PCB

Provides

Comments

Installs On

CHSUB112

Base Cabinet with power supply without

Provides 4 universal slots.

 

battery charger.

 

 

 

 

 

 

 

 

CHSUE112

Expansion Cabinet with power supply

Provides 4 universal slots.

 

without battery charger.

 

 

 

 

 

 

 

 

 

 

 

Base or

APSU112

Power Supply for CTX100.

Spare power supply.

Expansion

 

 

 

Cabinet

 

 

 

 

 

System Processor PCB. (Optional PCB

One per system. Supports 8 PCB

 

 

slots (4 slots in the Base Cabinet +

 

ACTU

attachments include: modem. Ethernet

4 more in the Expansion Cabinet).

 

10BaseT, DTMF Receiver/Busy Tone

 

 

 

Note The ACTU2A works with

 

 

Detector and Serial Interface Unit.

 

 

 

software R1.3 and higher.

 

 

 

 

 

ARCS

DTMF Receiver and ABR Circuits.

One per system. Provides 16

ACTU1 only

(Optional)

DTMF and 16 ABR circuits.

 

 

 

 

 

 

3-22

Strata CTX I&M 06/04

Page 124
Image 124
Toshiba CTX28 Install Other PCBs into the Cabinets, CTX100 Cabinet and Processor Components, Provides Comments Installs On