PCB Installation

RCOU3A, RCOS3A – Four-Circuit Loop Start CO Line Interface Unit

RCOU Installation

Note The decibel (dB) Pad switches SW101, SW201, SW301, and SW401 control excessive loudness resulting from close proximity to a Central Office or PBX telephone office by providing a -3 dB signal level drop to, or from, the PBX or CO when set to the 3 position. Switches are factory-set to the 0 (0 dB signal level drop) position.

To install an RCOU3A or RCOU1A PCB

1.If the Strata CTX system is within one mile of the PBX or Central Office, set the RCOU dB Pad switches SW101, SW201, SW301, and SW401 to the 3 (-3 dB signal level drop) position.

2.(RCOU3A only) For Mexico, the U.K, or Asia, insert the short jumper plug on the A Law side. For the U.S. and Canada, no plug is required. (No plug is the Mu Law assignment).

3.Insert the RCOU (component side facing right) into the appropriate slot and apply firm, even pressure to ensure proper mating of connectors. PCOU2 can be installed in place of RCOU, see the appropriate Configuration chapter.

4.After installing the RCOU, gently pull the PCB outward. If the connectors are properly mated, a slight resistance is felt.

Table 6-12 RCOU3A and RCOU1A Controls, Indicators, and Connectors

Control/Indicator/

Type of Component

Description

Connector

 

 

 

 

Lights to indicate that line circuit is in operation.

CO line circuit 1~4 indicators

Red LED

(CO line indicator will not light unless RCOU is

 

 

connected to a CO line).

 

 

 

J1 connector

Modular connector

Interface connector for CO line circuits 1 and 2.

 

 

 

J2 connector

Modular connector

Interface connector for CO line circuits 3 and 4.

 

 

 

Pad switch SW101 (circuit 1)

 

 

 

 

 

Pad switch SW201 (circuit 2)

2-position slide switch

Enables -3dB signal level drop for CO line

 

circuit.

Pad switch SW301 (circuit 3)

 

 

 

 

Pad switch SW401 (circuit 4)

 

 

 

 

 

RCOS connector P11, P12,

10-pin male connector

Interface connector for RCOS 4-circuit loop

P13, P14

start CO line unit.

 

 

 

 

Mu Law/A Law jumper plug

 

No jumper plug is the default for the U.S. and

 

Canada. For countries requiring A Law, insert

P2

3-terminal jumper

the jumper plug (provided in the PCB box) on

(RCOU3A only)

 

 

the A Law side.

 

 

 

 

 

PCB Installation