Toshiba CTX28 manual CTX100 Base 40 stations and 24 T1 and/or PRI lines, S102 S103 S104

Models: CTX28

1 495
Download 495 pages 33.26 Kb
Page 78
Image 78

Strata CTX Configuration

CTX100 Max. Capacity Configuration Examples

CTX100 Base Only: Digital Telephones and T1 and/or PRI lines

RPTU2 (PRI) is limited to 48 channels; RDTU2 and BPTU (T1) are limited to 64 channels.

Table 2-31 CTX100 CTX Base Cabinet with T1 and/or PRI lines

 

4 Universal Slots

 

40 Stations (Max.)

 

48 lines (Max.)

64 Stations + T1 and/or PRI or IP-QSIG lines combined (Max.)

Table No.

Stations

T1 and/or PRI lines

2-32

40

24/23

 

 

 

2-33

32

40/40

 

 

 

2-34

16

48/46

 

 

 

Table 2-32

CTX100 Base: 40 stations and 24 T1 and/or PRI lines

 

 

 

 

 

 

S101

 

S102

S103

S1041

 

BDKU/

 

BDKU/

RxTU22

ADKU

 

BDKS

 

BDKS

 

 

 

 

 

 

 

 

 

 

 

16 DKTs

 

16 DKTs

24 lines

8 DKTs

 

 

 

 

 

 

 

1.S104, only 8 DKTs because of cabinet power factor.

2.RxTU2 could be RDTU2 (T1), RPTU2 or BPTU (PRI).

Table 2-33 CTX100 Base: 32 stations and 40 T1 and/or PRI lines

S101

S102

S103

S104

RxTU2

BDKU/

RxTU21

BDKU/

 

BDKS

 

BDKS

16/15 lines

16 DKTS

24/23 lines

16 DKTS

 

 

 

 

1. RxTU2 could be RDTU2 (T1), RPTU2 or BPTU (PRI).

Table 2-34 CTX100 Base: 16 stations and 48 T1 and/or PRI lines

S101

 

S102

S103

S104

RxTU2

Vacant

RxTU21

BDKU/

(Shared)

BDKS

 

 

 

 

 

 

 

 

 

24/23lines

24/23 lines

16 DKTS

 

 

 

 

 

1. RxTU2 could be RDTU2 (T1), RPTU2 or BPTU (PRI).

2-32

Strata CTX I&M 06/04

Page 78
Image 78
Toshiba CTX28 CTX100 Base 40 stations and 24 T1 and/or PRI lines, 34 CTX100 Base 16 stations and 48 T1 and/or PRI lines