IP Telephony and QSIG Over IP

CTX IP Troubleshooting

LCD Network Failure Displays

When LCD Network failure occurs between BIPU and IPT, IPT displays one of the following LCD messages.

Table 9-8LCD Network Failure

 

Conditions

 

LCD Indication

Remarks

1.

Failed in TCP

 

 

 

 

 

BIPU TCP CONNECT

 

 

 

connection with BIPU.

 

ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Cut off TCP connection

 

 

 

 

BIPU TCP PORT IS

 

When this LCD message appears, IPT resets

 

with BIPU.

 

CLOSED

 

 

 

 

 

 

after 10 seconds.

 

 

 

 

 

3.

Keep alive error

 

 

 

 

 

 

 

 

(DCH data from BIPU

 

BIPU ALIVE PACKET STOP

 

 

 

was stopped 20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds or more.)

 

 

 

 

 

 

 

 

 

 

Collect CTX Trace Data on CTX SmartMedia Card

The Trace Data consists of an EventTrace, Error Log, Admin Log, and ProgData.The procedure is provided in the Strata CTX Programming Manual.

Collect BIPU Logs

1.Connect to PC by RS-232C cable and launch a terminal emulator software (Hyper Terminal, ProCom, etc.). See Figure 9-11.

CTX BIPU PCB Monitor Jack

Call-monitor jack

Dealer-supplied 6-wire telephone modular cord (cross-pinned)

PC with communication software, such as ProComm

PC DB9 or

DB25 Com port

Toshiba PPTC9 or

PPTC25F

RD 1

TD 2

DSR 3

DTR 4

DCD 5

SG 6

Call-monitor jack (RJ-12) pin numbering

6711

Figure 9-11 BIPU Monitor Jack

Serial port setings:

Baud rate: 9600

Data: 8 bit

Parity: none

Stop: 1 bit

Flow control: none

9-30

Strata CTX I&M 06/04

Page 360
Image 360