Strata CTX Configuration

Worksheet 6: Strata CTX670 Cabinet Slots

Worksheet 6: Strata CTX670 Cabinet Slots

The cabinet diagram below enables you to write in the PCBs installed in each cabinet slot. Use the PCB placement guideline below to place PCBs in the correct slots. Fill in the PCBs that go into each slot from the PCB quantities determined in the worksheets on the previous pages and the information provided in this worksheet. After completing Worksheet 6, Worksheet 7 must be completed to verify that the cabinet power factors do not exceed 85.

 

Main Location _______________

Remote Location

1___ 2___ 3___ 4___ 5___ 6___

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTX Cabinet Slots

 

 

 

 

 

Base

B101

B102

S101

S102

S103

S104

S105

S106

S107

S108

 

BEXU

BCTU

 

 

 

 

 

 

 

 

 

(AMDS, BSIS)

 

 

 

 

 

 

 

 

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BECU

BBCU

 

 

 

 

 

 

 

 

 

(BEXS, BSIS)

(BBMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cab 2

S201

S202

S203

S204

S205

S206

S207*

S208*

S209*

S210*

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cab 3

S301

S302

S303

S304

S305

S306

S307*

S308*

S309*

S310*

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cab 4

S401

S402

S403

S404

S405

S406

S407*

S408*

S409*

S410*

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cab 5

S501

S502

S503

S504

S505

S506

S507*

S508*

S509*

S510*

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cab 6

S601

S602

S603

S604

S605

S606

S607*

S608*

S609*

S610*

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cab 7

S701

S702

S703

S704

S705

S706

S707*

S708*

S709*

S710*

PCB Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

B101/B102 – Main processor slots. AMDS, BEXS, BBMS, BSIS are optional subassembly PCBs (see “CTX100 Processor Optional Subassemblies” on page 2-3).

Cabinet slots marked with * provide 8 time slots; all other slots provide 16 time slots.

BIPU-M and BIPU-Q can be installed in slots with 16 time slots only. Slots that provide 8 time slots (marked with *) do not support BIPU cards. BIPU PCBs can only be placed in 16 channel slots.

Important! If a BIPU-M or BIPU-Q is installed RCOU1A, RCOS1A RDDU1A, RGLU1A, RGLU2A, and two-wire REMU cards should not be installed to avoid excessive Echo Return Loss (ERL).

Any combination of up to 96 (basic processor) or 264 (expanded processor) RPTU, BPTU and RDTU channels can be installed in the CTX670.

RDTU, BPTU and RPTU PCBs can only be placed in odd slots of the Base Cabinet and slots S_01, S_03, and S_05 in any Expansion Cabinet. If 17 or more channels are used, the next highest slot adjacent to the RDTU, BPTU, or RPTU slot cannot be used. Slots adjacent to 8 or 16 channel RDTU, BPTU or RPTU PCBs can be used.

The maximum number of RDTU and/or RPTU cards is determined by the CTX system line capacity. Any number of line interface cards (RDTU, RPTU, BPTU, RCOU/RCOS, REMU, RDDU, RGLU, BIPU-Q1A) can be installed, providing that the quantity of lines and channels do not exceed the CTX system’s line capacity.

If only 16 B channels of PRI are needed, another card can be installed in the next slot. The position of D-channels can still be set to the 24th channel because the data of the D-channel is passed through the data highway, not the PCM highway. The position of the D-channel doesn’t affect the installation of cards in the CTX.

Network clock signals can only be derived from digital trunk PCBs, such as the RDTU and RPTU, that are installed in the Base Cabinet (Master) location. Do not install these digital trunk cards into the Remote Cabinets.

BDKU, PDKU, RDSU without Speaker OCA can be in any available slot in any cabinet. BDKU, PDKU, RDSU with Speaker OCA can be in any available slots in the Base and S_01~S_06 in all Exp. Cabs.

BDKU/BDKS or BWDKU without Speaker OCA can be in any available slots in the Base and S_01~S_06 in the Expansion Cabs. It is recommended you not install Speaker OCA telephones on the BWDKU or BDKU/BDKS. If you do, it must be in an odd slot and the next slot must be vacant.

If the BWDKU is placed in slots 7~10, it must be set for 8 circuits with PCB jumper and in Program 100.

Maximum 80 digital telephones per shelf due to the Power Factor restriction.

For more details, see the following Placement Guidelines section.

Strata CTX Configuration

Strata CTX I&M 06/04

2-37

Page 83
Image 83
Toshiba CTX28 manual Worksheet 6 Strata CTX670 Cabinet Slots