PCB Installation

Network Requirements

Network Requirements

The system network requirements are provided in Table 6-21.

Table 6-21 PCB Network Requirements

PCB/Interface

Facility Interface Code

Network Jack

Ringer

Universal Service

Equivalence

Order Code

 

 

 

RSTU2/RDSU1

OL13B (RSTU2, –24V)

RJ21X

N/A

9.0F

(Off-premises Station)

OL13C (RSTU2, RDSU with R48S-48V)

 

 

 

 

 

 

 

 

RCOU/RCOS2

02LS2

RJ14C/RJ21X

0.3B

N/A

(loop start line)

(all others)

 

 

 

 

 

 

 

 

RDDU

02RV2-T (Dealer-supplied CSU)

RJ14C/RJ21X

0.0B

AS.2

 

 

 

 

 

 

TL11M, 2-wire

RJ2EX

 

 

REMU type 1 or type 2

TL31M, 4-wire

RJ2GX

Not Available

9.0F

TL12M, type 2, 2-wire

RJ2FX

(N/A)

 

 

 

TL32M, type 2, 4-wire

RJ2HX

 

 

 

 

 

 

 

RGLU22 (ground or loop

02GS2 (ground)

RJ14C/RJ11CX

0.3B

N/A

start line)

02LS2 (loop)

 

 

 

 

 

 

 

 

RDTU (DS-1/T1)3

(See last bullet note on Note 2 below.)

RJ48C/RJ48X/

N/A

6.0P

RJ48M

 

 

 

 

 

 

 

 

 

RCIU2/RCIS (Caller ID)

N/A

RJ21X/RJ14C

0.3B

N/A

 

 

 

 

 

RPTU (PRI)4, 5

04DU9-1SN (Dealer-supplied CSU)

RJ48C/RJ48M

 

 

RPTU (QSIGI)

04DU9-1SN (Dealer-supplied CSU)

RJ48C/RJ48M

 

 

 

 

 

 

 

RBSU/RBSS (S/T, BRI)3

02IS5 (Dealer-supplied NT-1)

RJ48C/RJ48X

N/A

6.0P

RBUU/RBUS (U, BRI)3

02IS5

RJ48C/RJ48X

 

 

RMCU/RCMS (CAMA)

02RV2-O

RJ11C/RJ21-X

 

 

 

 

 

 

 

1.Only RDSU ckts. 1~4 provide Off-premises Station (OPS) ability. RDSU must use OL13A or OL13B if providing –24 volt loop voltage. If equipped with the –48 volt loop option PCB (R48S), OL13A, OL13B, or OL13C may be used for OPS connection.

2.Loop current requirements for Strata loop and ground start lines: 20 milliamperes (mA) min./120 mA max.

3.When ordering DS-1/T1 circuits, six items must be specified:

The number of channels per T1 circuit, fractional increments are normally 8, 12, or 16 channels, full service is 24 channels. Unused channels must be bit-stuffed.

CO line types assigned to each channel: Loop Start, Ground Start, Tie (Wink or Immediate Start), DID (Wink or Immediate).

Frame Format Type: Super Frame (SF) or Extended Super Frame (ESF). The T1 provider normally specifies the Frame Format to be used, either is adequate for CO digital voice lines. ESF provides a higher level of performance monitoring, but requires trained personnel and the ESF CSU normally costs more than an SF only CSU.

Line Code Type: Alternate Mark Inversion (AMI) or Bipolar 8 Zero Substitution (B8ZS). The T1 provider normally specified the Line Code to be used, either is adequate for T1 CO digital voice lines.

The customer may have to provide the Channel Service Unit (CSU) to interface the CTX T1 circuit to the Telco T1 circuit. (CSUs are a Telco requirement.)

RDTU Network Channel Interface Codes: 04DU9-BN, 04DU9-DNZZ, 04DU9-1SN, 04DU9-1KN, 04DU9-1ZN.

4.For information on how to order ISDN PRI/BRI circuits, you should refer to the Toshiba ISDN Training CBT. ISDN circuits may require a customer-provided CSU for PRI and/or Terminal Adapter or Network Terminal units for BRI. In U.S. CSU/TAs must be UL-listed in the U.S. In Canada, they must be CSA certified.

5.RPTU2 is required for QSIG private networking.

6-42

Strata CTX I&M 06/04

Page 266