Like any other precision instrument, the densitometer must be calibrated before each use. Refer to its documentation for instructions on calibrating and using the densitometer.

After calibrating the densitometer, use it to get density measurements for the calibration page you printed.

Linearizing the Densitometer Data

Enter the densitometer measurements to calculate the adjustments necessary to correct printer performance to a linear standard.

1.Click Enter Curve/Linearize (fig. 4.23). The Densitometer Data Entry window appears (fig. 4.25).

Fig. 4.25 Densitometer Data Entry Window

2.Measure individual patches on the calibration page by placing the page on a white background; then, center the densitometer's lens over the patch and either click the black button on top of the XD-1 or click the measure button on the Densitometer Data Entry window (fig. 4.25). The measurement appears in the box to the right of the Measure button.

4-40 PC Setup