Xante 3 Series warranty Click OK to close the Linearization window

Models: 3 Series

1 320
Download 320 pages 458 b
Page 129
Image 129

3.

Make sure to enter the solid black (1) and solid white (2)

 

 

measurements first. Enter the number of the patch whose

±

 

densitometer measurement most closely matches (within

2%) the corresponding percentage in the enter the box numbers section (3).

For example, when you are reading for 2%, if the box labeled 7 measures 2%, enter the number 7 in the corresponding box.

Note: The calibration page blocks are numbered from 0 to

255.You may have to check several blocks to find the one that most closely matches the percentage in the Densitometer Data Entry window.

Also, it is not necessary to measure for each coverage value listed in the Densitometer Data Entry window, but it is recommended to do so to achieve more accurate results.

4.Click Graph to display a curve of your printer’s linear curve.

5.Click Linearize to continue. The Linearization window reappears (4.23)

Note: If you need to stop linearization (for example, to change the media type), you can click Cancel to stop.

6.Click Save (fig. 4.23) if you want to save the data file for future use. Then, specify a new file name and select a folder for saving the file. Click Save. Otherwise, skip to step 7.

7.Click OK to close the Linearization window.

Note: If you want to verify linearization, click the Verify Calibration button (4.23) before you close the Linearization window. When this page prints compare it to the original calibration page to verify the gamma correction; you should see an improvement in gray scale progression.