Image 83

6.Make the measurements indicated on the calibration page next

to boxes A through F, I, and J, recording each measurement in its corresponding box on the calibration page. The values in boxes G and H are fixed values and do not require you to make any measurements.

7.Compare the following pairs:

A to F

For example: A = 25

F = 25.5

B to D

B = 61

D = 61

C to H

C = 190

H = 190.5

E to G

E = 253

G = 254

I to J

I = 39

J = 39.5

The numbers in each pair should be the same or within a 0.5

mmdifference. If so, skip to step 11. If not (as in E and G in the example), continue to step 8.

8.Copy the recorded measurements in boxes A through F, I, and

J and the fixed values in boxes G and H from the calibration page to the corresponding boxes in the Enter Calibration

Values section of the More X-ACT window.

9.Click Update Printer. (Clicking this button sends the new calibration measurements to the printer so it can update.)

10.Repeat steps 5 through 9 until the measurements in the corresponding boxes are within .5 mm of each other.

Note: Your application printer properties must match your calibration settings. For example, if you chose User- defined 1 as your media type in the More X-ACT calibration window for 11" x 17" (tabloid) paper, you must choose User-defined 1 as your Media Weight in

your application printer properties when printing on 11" x 17" paper.

11.Click Ok to close the More X-ACT window.