5.Click Print Calibration Page. A test page similar to the one shown in the Calibration Page section prints.

A

A

 

Measure dashed line from left edge of

 

 

paper to top arrow tip; enter results in

 

B

millimeters in box A.

D

C

B

Measure dashed line from top edge of paper to left arrow tip; enter results in millimeters in box B.

C

Measure solid horizontal line from left arrow tip to right arrow tip; enter results in millimeters in box C. This should be close to the value shown in box H.

D

Measure dashed line from top edge of paper to right arrow tip; enter results in millimeters in box D.

EE

Measure solid vertical line from top arrow tip to bottom arrow tip; enter results in millimeters in box E. This should be close to the value shown in box G.

I

F

Measure dashed line from left edge of

paper to bottom arrow tip; enter results in millimeters in box F.

F

I

Measure dashed line from bottom edge of paper to left arrow tip; enter results in

millimeters in box

I.

G254.0

H190.5

J

Measure dashed line frombottom edge of paper to bottom arrow tip; enter results in millimeters in box J.

J

Fig. 4.30 X-ACT Calibration Page

6.Make the measurements indicated on the calibration page next

to boxes A through F, I, and J, recording each measurement in its corresponding box on the calibration page. The values in boxes G and H are fixed values and do not require you to make any measurements.

7.Copy the recorded measurements in boxes A through F, I, and

J and the fixed values in boxes G and H from the calibration page to the corresponding boxes in the Enter Calibration Values section of the More X-ACT window.

8.Click Update Printer.

Note: When you click Update Printer, a window displays the Printer Calibrated message. Click OK to continue and

all the numbers clear automatically from the boxes in

the Enter Calibration Values section.Do not enter the values again. Also, if you click Reset Printer, you can

reset all settings or the selected media type.

___________________________________________

PC Setup 4-49

Page 137
Image 137
Xante 3 Series warranty Reset all settings or the selected media type, Measure dashed line from left edge