IBM 5000 manual Removing the Rack Model from a Rack Enclosure

Models: 5000

1 204
Download 204 pages 30.32 Kb
Page 114
Image 114
To remove the Netfinity 5000 server from a rack enclosure:

Removing the Rack Model from a Rack Enclosure

To remove the Netfinity 5000 server from a rack enclosure:

1.Remove the screws from each front bracket. Set the screws asid use.

2. Slide the server out of the rack.

3. If you have a modem or fax machine attached to the server, d telephone line from the wall outlet and the server.

Note: If you are in the United Kingdom, you must perform this st disconnecting the power cord.

4. Disconnect all cables and power cords from the rear of the ser

5. Remove the two screws from the cable-arm bracket.

6. Press the safety release latch on each slide rail.

7.Lift the server at a slight angle, and pull it from the slide ra server on a flat, nonconductive surface.

Chapter 5. Installing a Server in a Rack105Enclosure