IBM 5000 manual Ÿ If, Using the Configuration/Setup Utility, Arrow→ key

Models: 5000

1 204
Download 204 pages 30.32 Kb
Page 36
Image 36

Using the Configuration/Setup Utility

When a power-on password is set, POST does not complete until you enter password. If you forget the power-on password, you can regain access server through one of the following methods:

Ÿ If

an

administrator

password has been set, enter the administrator

the

power-on

prompt (see “Using the Administrator

Password

Menu”

on

page 27

for

details). Start the Configuration/Setup

Utility

program

and

the

power-on

password

as described in steps 1

through

5 above.

ŸUse the Bypass-Power-On-Password switch on the system board to tempo bypass the power-on password.

1.See “Preparing to Install Options” on page 43 through “Preparing a

Model” on page 44 or through “Preparing a Rack Model” on page 46 instructions on powering off the server and removing the cover. The to the system-board diagram inside your server for the location switch block.

2. Locate switch 8 (see “System Board Switches” on page 170).

3. Set switch 8 on the switch block to On, to bypass the power-on

4. Restart the server, then start the Configuration/Setup Utility pr change the power-on password as described in steps 1 through 5

5. Turn the server off again.

6. Set switch 8 back to Off.

7. Restart the server.

To delete a power-on password:

1.SelectPower-on Password from the System Security menu; then, press

Enter.

 

The Power-on

Password

menu appears.

 

 

2.

SelectDelete

Power-on

Password;

 

then,

pressEnter.

 

3.

A

confirmation

window appears.EnterPressto

delete

the power-on password.

 

Press Esc

 

to

cancel

the

request

and

return

to the System Security m

To

allow

the

server

to

start

in

unattended mode

when

a power-on

password

is

set:

 

 

 

 

 

 

 

 

 

 

Note:

 

The Allow

for

unattended

boot

with

password

 

data

field must be set to

 

 

 

On

for the system to support locally or remotely scheduled syst

 

 

 

shutdowns

or

restarts

in

unattended-start

mode.

1.SelectPower-on Password from the System Security menu; then, press

Enter.

The Power-on Password menu appears.

2. SelectAllow

for unattended

boot

with password

. Press the Left ←Arrow) (

or Right

Arrow→) key(

to

toggle theOn

.entry to

If no power-on password is set on the server, this option has no eff

26 Netfinity 5000 Server Hardware Information and Procedures

Page 36
Image 36
IBM 5000 manual Ÿ If, Using the Configuration/Setup Utility, Arrow→ key