POST Beep Codes

POST Beep Code Table

Beep Code

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1-2

Microprocessor

 

register

test

has

failed.

 

 

 

 

1-1-3

CMOS write/read test has failed.

 

 

 

 

 

 

 

 

1-1-4

BIOS ROM checksum has failed.

 

 

 

 

 

 

 

 

 

1-2-1

Programmable

Interval

Timer test

has

failed.

 

 

 

 

1-2-2

DMA

initialization

has

failed.

 

 

 

 

 

 

 

 

 

 

1-2-3

DMA page register write/read test has failed.

 

 

 

2-1-1

Secondary DMA register test has failed.

 

 

 

 

 

2-1-2

Primary DMA register test has failed.

 

 

 

 

 

2-1-3

Primary interrupt mask register test has failed.

 

 

 

2-1-4

Secondary interrupt mask register test has failed.

 

 

2-2-1

Interrupt vector loading has failed.

 

 

 

 

 

 

2-2-2

Keyboard

controller

test

has

failed.

 

 

 

 

 

 

2-2-3

CMOS

power

failure

and

 

checksum

checks

have

failed.

 

 

2-2-4

CMOS configuration information validation has failed.

 

 

 

2-3-2

Screen memory test has failed.

 

 

 

 

 

 

 

 

 

2-3-3

Screen retrace tests have failed.

 

 

 

 

 

 

 

2-3-4

Search for video ROM has failed.

 

 

 

 

 

 

 

 

2-4-1

Screen test indicates the screen is

operable.

 

 

 

3-1-1

Timer tick interrupt test has failed.

 

 

 

 

 

 

3-1-2

Interval

timer

channel

2

test

has

failed.

 

 

 

 

3-1-3

RAM

test

has

 

failed

above

address

hex

0FFFF.

 

 

 

3-1-4

Time-of-Day clock test has failed.

 

 

 

 

 

 

 

 

3-2-1

Serial port test has failed.

 

 

 

 

 

 

 

 

 

 

3-2-2

Parallel

port

test

has

failed.

 

 

 

 

 

 

 

 

 

3-2-3

Math Coprocessor test has failed.

 

 

 

 

 

 

 

 

3-2-4

Comparison of CMOS memory size

against

 

actual

has

failed.

 

 

3-3-2

Critical

 

SM

bus

error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action:

Have the

system

 

serviced.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2-4

RAM refresh verification has failed.

 

 

 

 

 

 

1-3-1

First 64 Kb RAM test has

failed.

 

 

 

 

 

 

 

 

1-3-2

First 64 Kb

RAM

parity

 

test

has

failed.

 

 

 

 

 

3-3-1

A memory size mismatch has occurred.

 

 

 

 

 

 

 

Action: Reseat the memory modules. If the problem persists, have the syst

 

serviced.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-3-3

No

memory

in

system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action:

Install

 

or

reseat

the memory modules. If the problem persists, the

 

may

be

 

a

failing

memory

module

or

a

faulty memory socket. Try the identif

 

DIMM

(LED

is

illuminated)

 

in

a

different

memory socket. If

the error occur

 

new location, replace the failing DIMM. Otherwise,

have the

 

system serviced

 

 

 

 

 

 

 

 

 

 

 

 

 

2-3-1

Screen

initialization

has

failed.

 

 

 

 

 

 

 

 

Action: Reseat the optional video adapter, if any. If the problem persis system serviced.

124 Netfinity 5000 Server Hardware Information and Procedures

Page 132
Image 132
IBM 5000 manual Post Beep Code Table