POST Messages

POST Message

Description

 

 

 

 

 

 

 

00019501

Processor 1 is not functioning.

 

 

 

 

Action:

Replace the primary microprocessor. (The

Primary

Microprocessor Err

 

LED

on

the

system board will be on. See “System

Board

LEDs” on page 168

 

the

location

of

the LED.)

 

 

 

 

If the problem persists, have the system serviced.

 

 

 

 

 

 

 

 

 

 

 

00019502

Processor

2

is

not

functioning.

 

 

 

Action: Replace the secondary microprocessor. (The Secondary Microprocesso Error LED on the system board will be on. See “System Board LEDs” on pag for the location of the LED.)

If the problem persists, have the system serviced.

00019701 Processor 1 failed the built-in self test.

Action: Replace

the

primary

microprocessor. (The Primary

Microprocessor Err

LED

on the system board will be on. See “System Board

LEDs” on page 168

the

location of

the

LED.)

 

 

 

If

the problem

persists,

have the system serviced.

 

 

 

 

 

 

 

 

 

00019702 Processor 2 failed the built-in self-test.

Action: Replace the secondary microprocessor. (The Secondary Microprocesso Error LED on the system board will be on. See “System Board LEDs” on pag for the location of the LED.)

If the problem persists, have the system serviced.

01298001 No update data for the processor 1 (the primary microprocessor).

Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.

01298002 No update data for processor 2 (the secondary microprocessor).

Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.

01298101 Bad update data for processor 1 (the primary microprocessor).

Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.

01298102 Bad update data for processor 2 (the secondary microprocessor).

Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.

I9990301 A hard disk drive error occurred.

Action: Have the system serviced.

I9990305 POST could not find an operating system.

Action: Install an operating system. If you have already installed the o system, check the drive startup sequence (see “Start Options” on page drive sequence is correct, run the diagnostic tests to verify that th functioning correctly. If there is a problem with the hard disk drive sector), you might have to reinstall the operating system.

If you cannot reinstall the operating system, have the system serviced.

I9990650AC power has been restored.

 

Action: No

action is required. This message appears each time AC power

 

restored

to

the

server after

an AC

power loss.

 

 

 

 

 

 

 

Other Numbers

POST

found

an error.

 

 

 

 

Action:

Follow

the

instructions on

the

screen.

 

 

 

 

 

 

 

 

 