POST Messages
POST Message | Description |
|
|
|
|
|
|
| |
00019501 | Processor 1 is not functioning. |
|
|
| |||||
| Action: | Replace the primary microprocessor. (The | Primary | Microprocessor Err | |||||
| LED | on | the | system board will be on. See “System | Board | LEDs” on page 168 | |||
| the | location | of | the LED.) |
|
|
| ||
| If the problem persists, have the system serviced. |
|
| ||||||
|
|
|
|
|
|
|
|
| |
00019502 | Processor | 2 | is | not | functioning. |
|
|
|
Action: Replace the secondary microprocessor. (The Secondary Microprocesso Error LED on the system board will be on. See “System Board LEDs” on pag for the location of the LED.)
If the problem persists, have the system serviced.
00019701 Processor 1 failed the
Action: Replace | the | primary | microprocessor. (The Primary | Microprocessor Err | ||
LED | on the system board will be on. See “System Board | LEDs” on page 168 | ||||
the | location of | the | LED.) |
|
|
|
If | the problem | persists, | have the system serviced. |
|
| |
|
|
|
|
|
|
|
00019702 Processor 2 failed the
Action: Replace the secondary microprocessor. (The Secondary Microprocesso Error LED on the system board will be on. See “System Board LEDs” on pag for the location of the LED.)
If the problem persists, have the system serviced.
01298001 No update data for the processor 1 (the primary microprocessor).
Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.
01298002 No update data for processor 2 (the secondary microprocessor).
Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.
01298101 Bad update data for processor 1 (the primary microprocessor).
Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.
01298102 Bad update data for processor 2 (the secondary microprocessor).
Action: Update the system BIOS to a level that supports the microproce installed in the server. See the “Getting Help Information”Server section of t Libraryfor information about obtaining updates from the World Wide Web.
I9990301 A hard disk drive error occurred.
Action: Have the system serviced.
I9990305 POST could not find an operating system.
Action: Install an operating system. If you have already installed the o system, check the drive startup sequence (see “Start Options” on page drive sequence is correct, run the diagnostic tests to verify that th functioning correctly. If there is a problem with the hard disk drive sector), you might have to reinstall the operating system.
If you cannot reinstall the operating system, have the system serviced.
I9990650AC power has been restored.
| Action: No | action is required. This message appears each time AC power | ||||||
| restored | to | the | server after | an AC | power loss. | ||
|
|
|
|
|
|
| ||
Other Numbers | POST | found | an error. |
|
|
| ||
| Action: | Follow | the | instructions on | the | screen. | ||
|
|
|
|
|
|
|
|
|
Chapter 6. Solving Problems 121