THE 80286 INSTRUCTION SET

LMSW-Load Machine Status Word

OpcodeInstruction ClocksDescription

OF 01 /6

LMSWew

3,mem=6

Load EA word into Machine Status Word

FLAGS MODIFIED

None

FLAGS UNDEFINED

None

OPERATION

The Machine Status Word is loaded from the source operand. This instruction may be used to switch to protected mode. If so, then it must be followed byan intra-segment jump to flush the instruction queue. LMSW will not switch back to Real Address Mode.

LMSW appears only in operating systems software. It does not appear in applications programs.

PROTECTED MODE EXCEPTIONS

#GP(O) if the current privilege level is not O. #GP(O) for an illegal memory operand effective address in the CS, DS, or ES segments; #SS(O) for an illegal address in the SS segment.

REAL ADDRESS MODE EXCEPTIONS

Interrupt 13 for a word operand at offset OFFFFH.