Intel 80287, 80286 manual Machine Status Word, MSW Bit Functions

Models: 80287 80286

1 515
Download 515 pages 45.04 Kb
Page 182
Image 182

SYSTEM CONTROL AND INITIALIZATION

SLDT (store LDT) can be executed at any privilege level. SLDT stores the local descriptor table selector from the program visible portion of the LDTR register.

Task Register loading or storing is again similar to that of the LDT. The LTR instruction, operating only at level 0, loads the LTR at initialization time with a selector for the initial TSS. LTR does NOT cause a task switch; it just changes the current TSS~ Note that the busy bit of the old TSS descriptor is not changed while the busy bit of the new TSS selector must be zero and will be set by LTR. The LDT and any segment registers referring to the old LDT should be reloaded. STR, which permits the storing of TR contents into memory, can be executed at any privilege level. LTR is not usually needed after initialization because the TR is managed by the task-switch operation.

10.2.2 Machine Status Word

The Machine Status Word (MSW) indicates the 80286 configuration and status. It is not part of a task's state. The MSW word is loaded by the LMSW instruction executed in real address mode or at privilege level 0 only, or is stored by the SMSWinstruction executing at any privilege level. MSW is a 16-bit register, the lower four bits of which are used by the 80286. These bits have the meanings shown in table 10-1. Bits 15-4 of the MSW will be used by the 80386. 80286 software should not change these bits. If the bits are changed by the 286 software, compatibility with the 80386 will be destroyed.

The TS flag is set under hardware control and reset under software control. Once the TS flag is set, the next instruction using a processor extension causes a processor extension not-present exception (#7). This feature allows software to test whether the current processor extension state belongs to the current task as discussed in section 11.4. If the current processor extension state belongs to a different task, the software can save the state of any processor extension with the state of the task that uses it. Thus, the TS bit protects a task from.processor extension errors that result from the actions of a previous

task..

The CLTS instruction is used to reset the TS flag after the exception handler has set up the proper processor extension state. The CLTS instruction can be executed at privilege level 0 only.

Bit

Table 10-1.MSW Bit Functions

NameFunction

Position

0PE Erotected mode e.nable places the 80286 into protected mode and cannot be cleared except by RESET.

i ivit' Munitor'jJfOCt;55UI eXLeiiSioii a::uV".;~ \lJA~T ::1:;tr~ctlc:1e to ca~ee a ....nrn,------..OQc::nr

. .

extension not-present exception (number 7) if TS is also set.

2EM Emulate processor extension causes a processor extension not-present excep- tion (number 7) on ESC instructions to allow a processor extension to be emulated.

3TS Iask switched indicates the next instruction using a processor extension will cause exception 7, allowing software to test whether the current processor extension context belongs to the current task.

10-4

Page 182
Image 182
Intel 80287, 80286 manual Machine Status Word, MSW Bit Functions