MERLIN LEGEND Communications System Release 5.0

Issue 1

System Manager’s Guide 555-650-118

June 1997

 

 

6Managing the System

Adding a CTI Link

Page 6-91

To busy-out and then restore the MLX module, follow the steps below:

1.Use one of the following procedures. Note that you select the Maintenance option from the Main menu, not the System Programming menu.

Console Procedure

To busy-out a module:

 

MenuMaintenanceSlotDial slot

 

no.EnterBusy-OutYes

PC Procedure

To￿busy-out a module:

 

￿Type slot no.￿￿￿

The screen displays progress messages and informs you when the busy-out is complete. Service on any facilities and/or extensions is suspended.

2.Exit the Maintenance menu and return to the System Programming menu. To add a CTI link, follow the procedures at the end of this topic. To remove

one, see ‘Removinga CTI Link’’ on page 6-92.

3.Restore the module to service. Use one of the following procedures:

Console Procedure

To restore a module:

 

MenuMaintenanceSlotDial slot

 

no.EnterRestoreYes

PC Procedure

To￿restore a module:

 

￿Type slot no.￿￿￿

The screen displays progress messages and informs you when the restore is complete. Service resumes on affected facilities and/or extensions.

Task List: Adding a CTI Link

6

Obtain Form 2a, System Numbering: Extension Jacks.

Plan the CTI link addition using the planning guidelines above; record the new values on Form 2a.

If necessary, read “Auxiliary Equipment” in System Programming, Chapter 4, for additional information.

Follow the procedure in the preceding topic, “Busying-Out and Restoring the MLX Module,” to terminate service on the module where the CTI link is planned.

oOpen the System Programming menu from the console or a PC with SPM.

Program the change(s), following the appropriate instructions for “Auxiliary Equipment” in System Programming, Chapter 4, or the appropriate summary programming instructions below. To specify the CTI link extension, use the main extension number (for example, extension 12 in a 2-digit numbering plan), not the adjunct extension number (for example, extension 712 in a 2-digit plan).

Page 309
Image 309
Lucent Technologies 5 manual Task List Adding a CTI Link, One, see ‘Removing‘ a CTI Link’’ on