MERLIN LEGEND Communications System Release 5.0

Issue 1

System Manager’s Guide 555-650-118

June 1997

C System Capacities

 

 

Page C-2

 

 

Similarly, although the 100D module has only one jack, it can serve up to 24 endpoints (emulated, T1 digital, or PRI facilities). Thus, you can configure the system to connect up to 80 lines/trunks and 255 extension endpoints, a total of 335 endpoints.

NOTE:

The system has a time-slot capacity of 216. If more than 216 endpoints are in use at the same time, blocking can occur.

Table C–1 lists the hardware and software capacities of the system. Some constraining factors appear with a checkmark (￿) and are explained at the end of the table.

If you are planning to expand your system, contact your Lucent Technologies representative for additional considerations.

Table C–1. Hardware and Software Capacities

 

Limit

Constraining Factor

Allowed/Disallowed Lists

 

 

Number of lists

8

 

Entries per list

10

 

Digits per entry

7

 

 

 

 

Automatic Route Selection

 

 

Number of ARS tables

16

 

Subpatterns per table

2

 

Routes per subpattern

6

 

Entries per table

100

 

Entries across all tables

1,600

 

Default tables

4

 

 

 

 

Callback

 

 

Number of calls in queue

64

 

 

 

 

Continued on next page

Page 396
Image 396
Lucent Technologies 5 manual Table C-1. Hardware and Software Capacities, Limit Constraining Factor