User Manual for the NETGEAR 7300S Series Layer 3 Managed Switch Software

Table 12-2.

Switch stack configuration scenarios (continued)

 

 

Stack master election specifically determined by

The stack member with the higher MAC address is

the MAC address

elected stack master.

• Assuming that both stack members have the

 

same priority value and software image, restart

 

both stack members at the same time.

 

Add a stack member

The stack master is retained. The new switch is

• Power off the new switch

added to the switch stack.

• Through their stacking ports, connect the new

 

switch to a powered-on switch stack.

 

• Power on the new switch.

 

 

 

Stack master failure

Based on "Stack Master Election and Re-Election"

• Remove (or power off) the stack master.

on page 5, one of the remaining stack members

 

 

becomes the new stack master. All other stack

 

 

members in the stack remain as stack members

 

 

and do not reboot.

 

 

 

Stacking Recommendations

The purpose of this section is to collect notes on recommended procedures and expected behavior of stacked FSM7328S/FSM7352S. Procedures addressed initially are listed below.

Initial installation and power-up of a stack.

Removing a unit from the stack

Adding a unit to an operating stack

Replacing a stack member with a new unit

Renumbering stack members

Moving the master to a different unit in the stack

Removing a master unit from an operating stack

Merging two operational stacks

Preconfiguration

Upgrading firmware

Migration of configuration with a firmware upgrade

12-10

Managing Switch Stacks

202-10088-01, March 2005

Page 322
Image 322
NETGEAR NETGEAR user manual Stacking Recommendations