User Manual for the NETGEAR 7300S Series Layer 3 Managed Switch Software

Allow New Telnet Sessions Indicates that new telnet sessions will not be allowed when set to no. The factory default value is yes.

show serial

This command displays serial communication settings for the switch.

Format

show serial

Mode

Privileged EXEC and User EXEC

Serial Port Login Timeout (minutes) Specifies the time, in minutes, of inactivity on a

 

Serial port connection, after which the Switch will close the con-

 

nection. Any numeric value between 0 and 160 is allowed, the

 

factory default is 5. A value of 0 disables the timeout.

Baud Rate

The default baud rate at which the serial port will try to connect.

 

The available values are 1200, 2400, 4800, 9600, 19200,

 

38400,57600, and 115200 baud. The factory Default is 9600

 

baud.

Character Size

The number of bits in a character. The number of bits is always 8.

Flow Control

Whether Hardware Flow-Control is enabled or disabled. Hard-

 

ware Flow Control is always disabled.

Stop Bits

The number of Stop bits per character. The number of Stop bits is

 

always 1.

Parity Type

The Parity Method used on the Serial Port. The Parity Method is

 

always None.

show serviceport

This command displays service port configuration information.

Format

show serviceport

Mode

Privileged EXEC

IP Address

The IP address of the interface. The factory default value is

 

0.0.0.0

Subnet Mask

The IP subnet mask for this interface. The factory default value is

 

0.0.0.0

Default Gateway

The default gateway for this IP interface. The factory default

 

value is 0.0.0.0

 

 

8-26

Switching Commands

202-10088-01, March 2005

Page 94
Image 94
NETGEAR NETGEAR user manual Show serial, Show serviceport