Chapter 13 xDSL Port Setup

13.11 PPVC Setup Screen

Use this screen to view and configure PPVCs.

To open this screen, click Basic Setting, xDSL Port Setup, PPVC Setup.Figure 53 PPVC Setup

The following table describes the labels in this screen.

Table 23 PPVC Setup

LABEL

DESCRIPTION

xDSL Port Setup

Click xDSL Port Setup to go to the screen where you can configure DSL port

 

settings (see Section 13.7 on page 109).

 

 

VC Setup

Click VC Setup to open the VC Setup screen where you can configure VC

 

settings for the DSL ports (see Section 13.9 on page 116).

 

 

Port

Use this drop-down list box to select a port for which you wish to configure

 

settings.

 

 

Encap.

Select the encapsulation type (llc or vc) for this PPVC.

 

 

VPI

Type the Virtual Path Identifier for this PPVC.

 

 

VCI

Type the Virtual Circuit Identifier for this PPVC. The IES-612-51A uses this PVC

 

channel internally. This PVC is not needed on the subscriber’s device. This PVC

 

cannot overlap with any existing PVCs on this port.

 

 

PVID

Type a PVID (Port VLAN ID) to assign to untagged frames received on this

 

PPVC.

 

 

Priority

Use the drop-down list box to select the priority value (0 to 7) to add to incoming

 

frames without a (IEEE 802.1p) priority tag.

 

 

Add / Modify

Click Add / Modify to save PPVC settings for a port.

 

In order to change a port’s PPVC settings, just select the port from the Port

 

drop-down list box and then configure the settings you want. These settings

 

replace the port’s old settings when you click Add / Modify.

 

Clicking Add / Modify saves your changes to the IES-612-51A’s volatile

 

memory.

 

The IES-612-51A loses these changes if it is turned off or loses power, so use

 

the Config Save link on the navigation panel to save your changes to the non-

 

volatile memory when you are done configuring.

 

 

Cancel

Click Cancel to start configuring the screen again.

 

 

 