Chapter 7 System Information
The following table describes the labels in this screen.
Table 11 System Info
LABEL | DESCRIPTION |
System Name | This field displays the device's model name. |
|
|
ZyNOS F/W Version | This field displays the version number of the device’s current firmware including |
| the date created. |
|
|
DSP Code Version | This field displays the Digital Signal Processor firmware version number. This is |
| the modem code firmware. |
|
|
Hardware Version | This is the version of the physical device hardware. This field may be blank. |
|
|
Serial Number | This is the individual identification number assigned to the device at the factory. |
| This field may be blank. |
|
|
Ethernet Address | This field refers to the Ethernet MAC (Media Access Control) address of the |
| device. |
|
|
Hardware Monitor |
|
|
|
Enable | Select this check box to turn the hardware monitor on or clear it to turn the |
| hardware monitor off. |
|
|
Temperature Unit | Select C to display all temperature measurements in degrees Celsius. Select F |
| to display all temperature measurements in degrees Fahrenheit. |
|
|
Temperature | Each temperature sensor can detect and report the temperature. Temperature |
| sensor 1 is near the DSL chipset. Temperature sensor 2 is near the central |
| processing unit. Temperature sensor 3 is at the hardware monitor chip. |
|
|
Current | This shows the current temperature at this sensor. |
|
|
MAX | This field displays the maximum temperature measured at this sensor. |
|
|
MIN | This field displays the minimum temperature measured at this sensor. |
|
|
Average | This field displays the average temperature measured at this sensor. |
|
|
Threshold (Low) | This field displays the lowest temperature limit at this sensor. |
|
|
Threshold (Hi) | This field displays the highest temperature limit at this sensor. |
|
|
Status | This field displays Normal for temperatures below the threshold and Over for |
| those above. |
|
|
Voltage(V) | The power supply for each voltage has a sensor that can detect and report the |
| voltage. |
|
|
Current | This is the current voltage reading. |
|
|
MAX | This field displays the maximum voltage measured at this point. |
|
|
MIN | This field displays the minimum voltage measured at this point. |
|
|
Average | This field displays the average voltage measured at this sensor. |
|
|
Threshold (Low) | This field displays the lowest voltage limit at this sensor. |
|
|
Threshold (Hi) | This field displays the highest voltage limit at this sensor. |
|
|
Status | Normal indicates that the voltage is within an acceptable operating range at this |
| point; otherwise Abnormal is displayed. |
| Use this section of the screen to configure the hardware monitor threshold |
| settings. |
|
|
New threshold | Configure new threshold settings in the fields below and click Apply to use |
Apply | them. |
|
|
Temperature (Hi) | Use these fields to configure the highest temperature limit at each sensor. |
|
|
Temperature (Lo) | Use these fields to configure the lowest temperature limit at each sensor. |
|
|
88 |
| |
| ||
|
|
|