Chapter 43 Alarm Commands

This command lists alarm settings.

The following example displays the supported minor level alarms for all alarm categories, facilities, types of alarm messages and conditions.

Figure 141 Alarm Tablelist Command Example

ras> alarm

table

facility snmp syslog severity

 

no alarm

condition

 

clearable

-------------------------

-------- ---- ------ -------- -------

--- -----

1

dsl

( 5000)line_up

local1

V

V

info

-

2

dsl

( 5001)line_down

local1

V

V

minor

V

3

dsl

( 5002)ad_perf_lol_thresh

local1

V

V

minor

V

4

dsl

( 5003)ad_perf_lof_thresh

local1

V

V

minor

V

5

dsl

( 5004)ad_perf_los_thresh

local1

V

V

minor

V

6

dsl

( 5005)ad_perf_lop_thresh

local1

V

V

minor

V

7

dsl

( 5006)ad_perf_es_thresh

local1

V

V

minor

V

8

dsl

( 5007)ad_perf_ses_thresh

local1

V

V

minor

V

9

dsl

( 5008)ad_perf_uas_thresh

local1

V

V

minor

V

10

dsl

( 5009)ad_atuc_loftrap

local1

V

V

minor

-

11

dsl

( 5010)ad_atuc_lostrap

local1

V

V

minor

-

12

dsl

( 5011)ad_atur_loftrap

local1

V

V

minor

-

13

dsl

( 5012)ad_atur_lostrap

local1

V

V

minor

-

14

dsl

( 5013)ad_atur_lprtrap

local1

V

V

minor

-

15

eqpt

(10000)vol_err

local1

V

V

critical

-

16

eqpt

(10001)temp_err

local1

V

V

critical

-

17

eqpt

(10002)hw_rtc_fail

local1

V

V

critical

-

18

eqpt

(10003)hw_mon_fail

local1

V

V

critical

-

19

eqpt

(10004)cold_start

local1

V

V

info

-

==================================== SNIP =================================

43.7 Log Format

The following table describes the columns in the list.

Table 92 Log Format

LABEL

DESCRIPTION

no

This is the index number of the alarm entry in this list display.

alarm

This is the category of alarms. eqpt represents equipment alarms. dsl

 

represents Digital Subscriber Line (DSL) alarms. enet represents Ethernet

 

alarms. sys represents system alarms.

 

 

condition

There is a condition code number for the specific alarm message and a text

 

description for the condition under which the alarm applies.

facility

This is the log facility (local1~local7) on the syslog server where the system is to

 

log this alarm. This is for alarms that send alarms to a syslog server.

snmp

This displays “V” if the system is to send this alarm to an SNMP server. It

 

displays “-“ if the system does not send this alarm to an SNMP server.

syslog

This displays “V” if the system is to send this alarm to a syslog server. It displays

 

“-“ if the system does not send this alarm to a syslog server.

severity

This is the alarm severity level (critical, major, minor or info).

clearable

This displays “V” if the alarm clear command removes the alarm from the

 

system. It displays “-“if the alarm clear command does not remove the alarm

 

from the system.

 

 

286

 