Chapter 43 Alarm Commands
This command lists alarm settings.
The following example displays the supported minor level alarms for all alarm categories, facilities, types of alarm messages and conditions.
Figure 141 Alarm Tablelist Command Example
ras> alarm | table | facility snmp syslog severity |
| ||||
no alarm | condition |
| |||||
clearable | |||||||
1 | dsl | ( 5000)line_up | local1 | V | V | info | - |
2 | dsl | ( 5001)line_down | local1 | V | V | minor | V |
3 | dsl | ( 5002)ad_perf_lol_thresh | local1 | V | V | minor | V |
4 | dsl | ( 5003)ad_perf_lof_thresh | local1 | V | V | minor | V |
5 | dsl | ( 5004)ad_perf_los_thresh | local1 | V | V | minor | V |
6 | dsl | ( 5005)ad_perf_lop_thresh | local1 | V | V | minor | V |
7 | dsl | ( 5006)ad_perf_es_thresh | local1 | V | V | minor | V |
8 | dsl | ( 5007)ad_perf_ses_thresh | local1 | V | V | minor | V |
9 | dsl | ( 5008)ad_perf_uas_thresh | local1 | V | V | minor | V |
10 | dsl | ( 5009)ad_atuc_loftrap | local1 | V | V | minor | - |
11 | dsl | ( 5010)ad_atuc_lostrap | local1 | V | V | minor | - |
12 | dsl | ( 5011)ad_atur_loftrap | local1 | V | V | minor | - |
13 | dsl | ( 5012)ad_atur_lostrap | local1 | V | V | minor | - |
14 | dsl | ( 5013)ad_atur_lprtrap | local1 | V | V | minor | - |
15 | eqpt | (10000)vol_err | local1 | V | V | critical | - |
16 | eqpt | (10001)temp_err | local1 | V | V | critical | - |
17 | eqpt | (10002)hw_rtc_fail | local1 | V | V | critical | - |
18 | eqpt | (10003)hw_mon_fail | local1 | V | V | critical | - |
19 | eqpt | (10004)cold_start | local1 | V | V | info | - |
==================================== SNIP =================================
43.7 Log Format
The following table describes the columns in the list.
Table 92 Log Format
LABEL | DESCRIPTION |
no | This is the index number of the alarm entry in this list display. |
alarm | This is the category of alarms. eqpt represents equipment alarms. dsl |
| represents Digital Subscriber Line (DSL) alarms. enet represents Ethernet |
| alarms. sys represents system alarms. |
|
|
condition | There is a condition code number for the specific alarm message and a text |
| description for the condition under which the alarm applies. |
facility | This is the log facility (local1~local7) on the syslog server where the system is to |
| log this alarm. This is for alarms that send alarms to a syslog server. |
snmp | This displays “V” if the system is to send this alarm to an SNMP server. It |
| displays |
syslog | This displays “V” if the system is to send this alarm to a syslog server. It displays |
| |
severity | This is the alarm severity level (critical, major, minor or info). |
clearable | This displays “V” if the alarm clear command removes the alarm from the |
| system. It displays |
| from the system. |
|
|