Chapter 34 Access Control

34.3.1 Supported MIBs

MIBs let administrators collect statistics and monitor status and performance. See Appendix on page 417 for the list of MIBs the IES-612-51A supports.

34.3.2 SNMP Traps

The IES-612-51A can send the following SNMP traps to an SNMP manager when an event occurs. ATUC refers to the downstream channel (for traffic going from the IES-612-51A to the subscriber). ATUR refers to the upstream channel (for traffic coming from the subscriber to the IES-612-51A).

Table 75 SNMPv2 Traps

TRAP NAME

DESCRIPTION

coldStart

This trap is sent when the IES-612-51A is turned on.

 

 

warmStart

This trap is sent when the IES-612-51A restarts.

 

 

linkDown

This trap is sent when the Ethernet link is down. Enterprise specific

 

(adsl_atuc_los) traps are sent when an ADSL link is down.

 

 

linkUp

This trap is sent when the Ethernet or ADSL link comes up.

 

 

authenticationFailure

This trap is sent when the SNMP community check fails.

 

 

reboot

This trap is sent when the system is going to reboot. The variable is the

 

reason for the system reboot.

 

 

overheat

This trap is sent when the system is overheated. The variable is the

 

current system temperature in Celsius.

 

 

overheatOver

This trap is sent when the system is no longer overheated. The

 

variable is the current system temperature in Celsius.

 

 

voltageOutOfRange

This trap is sent when the voltage of the system is out of the normal

 

range. The variable is the current voltage of the system in volts.

 

 

voltageNormal

This trap is sent when the voltage of the system is back within the

 

normal range. The variable is the current voltage of the system in volts.

 

 

thermalSensorFailure

This trap is sent when the thermal sensor fails.

 

 

adslAtucLof

This trap is sent when a Loss Of Frame is detected on the ATUC.

 

 

adslAturLof

This trap is sent when a Loss Of Frame is detected on the ATUR.

 

 

adslAtucLos

This trap is sent when a Loss Of Signal is detected on the ATUC.

 

 

adslAturLos

This trap is sent when a Loss Of Signal is detected on the ATUR.

 

 

adslAturLpr

This trap is sent when a Loss Of Power is detected on the ATUR.

 

 

adslAtucLofClear

This trap is sent when the Loss Of Frame detected on the ATUC is

 

over.

 

 

adslAturLofClear

This trap is sent when the Loss Of Frame detected on the ATUR is

 

over.

 

 

adslAtucLosClear

This trap is sent when the Loss Of Signal detected on the ATUC is

 

over.

 

 

adslAturLosClear

This trap is sent when the Loss Of Signal detected on the ATUR is

 

over.

 

 

adslAturLprClear

This trap is sent when the Loss Of Power detected on the ATUR is

 

over.

 

 

 

227