| Chapter 42 Command Examples |
Table 90 Log Messages (continued) |
| ||
LOG MESSAGE | TYPE |
| DESCRIPTION |
Sync with timeserver | WARN |
| The device was not able to synchronize the time with the time server at the |
<ip> failed! |
|
| listed IP address. |
Sync with timeserver | INFO |
| The device synchronized the time with the time server at the listed IP |
<ip> successful! |
|
| address. |
Received File <file>! | INFO |
| A file was uploaded to the |
|
|
| <file> - received file’s name |
Received Firmware | WARN |
| A checksum error was detected during an attempted FTP firmware upload. |
Checksum Error! |
|
|
|
Received Firmware | WARN |
| Someone attempted to upload a firmware file with a wrong identity via FTP. |
Invalid! |
|
|
|
Received Firmware Size | WARN |
| The file size was too large with an attempted FTP firmware upload. |
too large! |
|
|
|
THERMO LOW VOLTAGE: | WARN |
| The device’s voltage went above the accepted operating range. |
dev: <id> limit: |
|
| <id> 1=1.2 V, 2=1.8 V, 3=3.3 V, 4=18 V |
<threshold> value: |
|
| <threshold> - voltage limit |
<voltage>! |
|
| <voltage> - voltage of the DC power when logged |
THERMO LOW | WARN |
| The temperature was too low at one of the temperature sensors. |
TEMPERATURE: dev:<id> |
|
| <id> - |
threshold:<threshold> |
|
| 0: sensor near the ADSL chipset |
(degree C) |
|
| 1: sensor near the CPU |
value:<temp>(degree |
|
| 2: thermal sensor chip |
C)! |
|
| <threshold> - temperature limit |
|
|
| <temp> - temperature when the entry was logged |
|
|
|
|
THERMO OVER | WARN |
| The temperature was too high at one of the temperature sensors. |
TEMPERATURE: dev:<id> |
|
| <id> - |
threshold:<threshold> |
|
| 0: sensor near the ADSL chipset |
(degree C) |
|
| 1: sensor near the CPU |
value:<temp>(degree |
|
| 2: thermal sensor chip |
C)! |
|
| <threshold> - temperature limit |
|
|
| <temp> - temperature when the entry was logged |
|
|
|
|
THERMO OVER | INFO |
| The temperature at one of the temperature sensors has come back to |
TEMPERATURE released: |
|
| normal. |
dev:<id> |
|
| <id> - |
threshold:<threshold> |
|
| 0: sensor near the ADSL chipset |
(degree C) |
|
| 1: sensor near the CPU |
value:<temp>(degree |
|
| 2: thermal sensor chip |
C)! |
|
| <threshold> - temperature limit |
|
|
| <temp> - temperature when the entry was logged |
|
|
|
|
THERMO OVER VOLTAGE: | WARN |
| The voltage at one of the voltage sensors went above the accepted |
dev: <id> limit: |
|
| operating range. |
<threshold> value: |
|
| <id> 1=1.2v, 2=1.8v, 3=3.3v, 4=24v |
<voltage>! |
|
| <threshold> - voltage limit |
|
|
| <voltage> - voltage of the DC power when logged |
|
|
|
|
THERMO OVER VOLTAGE | INFO |
| The device’s voltage is back inside the accepted operating range. |
released: |
|
| <nominal> - nominal voltage of the DC power |
nominal:<nominal>(mV) |
|
| <voltage> - voltage of the DC power when logged |
value:<voltage> (mV)! |
|
|
|
| 279 |
|
|