| Chapter 53 Virtual Channel Management Commands |
<vci> | = | The VCI of the TLS PVC. |
<DS vcprofile | = | Assign a VC profile to use for this channel’s downstream |
|
| traffic shaping. |
[,US
vcprofile]>
=Assign a VC profile to use for policing this channel’s upstream traffic. The
<pvid> | = | 1 – 4094; the (second) VLAN Identifier to add to Ethernet |
|
| frames that the system routes using this PVC. |
<priority> | = | Set the IEEE 802.1p priority (0~7) to add to the traffic that |
|
| uses this PVC. |
This command sets the second VLAN tag to add to the packets from the PVC.
The following example adds VLAN tag 100 to traffic using the DEFVAL ATM profile on PVC (1/33) on port 2.
Figure 287 TLS PVC Set Command Example
ras> adsl tlspvc set 2 1 33 DEFVAL 100 0
53.9.3 TLS PVC Show CommandSyntax:
ras> adsl tlspvc show <portlist> [<vpi> <vci>]
where
<portlist> | = | The port number of the TLS PVC. You can specify a single |
|
| DSL port <1>, all DSL ports <*> or a list of DSL ports |
|
| <1,3,5>. You can also include a range of ports <1,5,6~10>. |
<vpi> | = | The VPI of the TLS PVC. |
<vci> | = | The VCI of the TLS PVC. |
This command displays the TLS settings for the specified port(s) or PVC(s). The following example shows the TLS settings on port 2.
Figure 288 TLS PVC Show Command Example
ras> | adsl tlspvc | show 2 | DS/US vcprofile | |
port | vpi | vci | pvid pri | |
2 | 1 | 33 | 100 0 | DEFVAL |
|
|
|
|
|
| 397 |
|
|