Chapter 28 PPPoA to PPPoE

 

Table 63 PPPoA to PPPoE (continued)

 

LABEL

DESCRIPTION

 

AC Name

This field is optional. Specify the hostname of a remote access concentrator if

 

 

there are two access concentrators (or BRAS) on the network or if you want to

 

 

allow PAE translation to the specified access concentrator. In this case, the IES-

 

 

612-51A checks the AC name field in the BRAS's reply PDU. If there is a

 

 

mismatch, the IES-612-51A drops this PDU. (This is not recorded as an PPPoE

 

 

AC System Error in the PPPoA to PPPoE Status screen, however.)

 

 

 

 

Service Name

This field is optional. Specify the name of the service that uses this PVC. This

 

 

must be a service name that you configure on the remote access concentrator.

 

 

 

 

Hellotime

Specify the timeout, in seconds, for the PPPoE session. Enter 0 if there is no

 

 

timeout.

 

 

 

 

Apply

Click this to add or save channel settings on the selected port.

 

 

This saves your changes to the IES-612-51A’s volatile memory. The IES-612-

 

 

51A loses these changes if it is turned off or loses power, so use the Config

 

 

Save link on the navigation panel to save your changes to the non-volatile

 

 

memory when you are done configuring.

 

 

 

 

Cancel

Click Cancel to start configuring the screen again.

 

 

 

 

Show Port

Select which DSL port(s) for which to display PPPoA to PPPoE conversion

 

 

settings.

 

 

 

 

Index

This field displays the number of the PVC. Click a PVC’s index number to open

 

 

the screen where you can look at the current status of this PPPoA-to-PPPoE

 

 

conversion. (See Section 28.3 on page 206.)

 

 

Note: At the time of writing, you cannot edit the VPI and VCI. If

 

 

you want to change them, add a new PVC with the desired

 

 

settings. Then, delete any unwanted PVCs.

 

 

 

 

Port

This field displays the number of the DSL port on which the PVC is configured.

 

 

 

 

VPI/VCI

This field displays the Virtual Path Identifier (VPI) and Virtual Circuit Identifier

 

 

(VCI). The VPI and VCI identify a channel on this port.

 

 

 

 

PVID

This is the PVID (Port VLAN ID) assigned to untagged frames or priority frames

 

 

(0 VID) received on this channel.

 

 

 

 

Priority

This is the priority value (0 to 7) added to incoming frames without a (IEEE

 

 

802.1p) priority tag.

 

 

 

 

Hellotime

This field displays the timeout for the PPPoE session, in seconds.

 

 

 

 

DS / US VC Profile

This shows which VC profile this channel uses for downstream traffic shaping.

 

 

The VC profile for upstream policing also displays if the channel is configured to

 

 

use one.

 

 

 

 

Access

This field displays the name of the specified remote access concentrator, if any.

 

Concentrator Name

 

 

 

 

 

Service Name

This field displays the name of the service that uses this PVC on the remote

 

 

access concentrator.

 

 

 

 

Select

Select the check box in the Select column for an entry, and click Delete to

 

Delete

remove the entry.

 

 

 

 

Select All

Click this to select all entries in the table.

 

 

 

 

Select None

Click this to un-select all entries in the table.

 

 

 

 

205