Chapter 14 xDSL Profiles Setup
Table 25 Port Profile (continued)
LABEL | DESCRIPTION |
IGMP Filter Profile | Click IGMP Filter Profile to open the IGMP Filter Profile screen where you can |
| configure IGMP multicast filter profiles (see Section 14.8 on page 135). |
|
|
Index | This is the port profile index number. |
|
|
Name | These are the names of individual profiles. The DEFVAL profile always exists |
| and all of the DSL ports have it assigned to them by default. You can use up to |
| 31 ASCII characters; spaces are not allowed. |
|
|
Latency Mode | This is the ADSL latency mode (Fast or Interleave) for the ports that belong to |
| this profile. |
|
|
Down/Up Stream | These are the maximum downstream and upstream transfer rates for the ports |
Rate (kbps) | that belong to this profile. |
|
|
Select | Select a profile’s Select radio button and click Modify to edit the profile. |
Modify |
|
|
|
Select | Select a profile’s Select radio button and click Delete to remove the profile. |
Delete |
|
|
|
| The rest of the screen is for profile configuration. |
|
|
Name | When editing a profile, this is the name of this profile. When adding a profile, |
| type a name (up to 31 characters) for the profile. |
|
|
Latency Mode | This field sets the ADSL latency mode for the ports that belong to this profile. |
| Select Fast mode to use no interleaving and have faster transmission (a “fast |
| channel”). This would be suitable if you have a good line where little error |
| correction is necessary. |
| Select Interleave mode to use interleave delay when transmission error |
| correction (Reed- Solomon) is necessary due to a less than ideal telephone line. |
| See Section 13.4 on page 108 for more on interleave delay. |
|
|
Up Stream | The following parameters relate to upstream transmissions. |
|
|
Max Rate | Type a maximum upstream transfer rate (64 to 4096 Kbps) for this profile. |
| Configure the maximum upstream transfer rate to be less than the maximum |
| downstream transfer rate. |
|
|
Min Rate | Type the minimum upstream transfer rate (32 to 4096 Kbps) for this port. |
| Configure the minimum upstream transfer rate to be less than the maximum |
| upstream transfer rate. |
|
|
Interleave Delay | Configure this field when you set the Latency Mode field to Interleave. Type |
| the number of milliseconds |
| transfers. It is recommended that you configure the same latency delay for both |
| upstream and downstream. |
|
|
Max SNR | Type the maximum upstream signal to noise margin |
|
|
Min SNR | Type the minimum upstream signal to noise margin |
| minimum upstream signal to noise margin to be less than or equal to the |
| maximum upstream signal to noise margin. |
|
|
Target SNR | Type the target upstream signal to noise margin |
| upstream signal to noise margin to be greater than or equal to the minimum |
| upstream signal to noise margin and less than or equal to the maximum |
| upstream signal to noise margin. |
|
|
Up Shift SNR | The upstream up shift signal to noise margin |
| signal to noise margin goes above this number, the device can attempt to use a |
| higher transfer rate. Configure the upstream up shift signal to noise margin to be |
| greater than or equal to the target upstream signal to noise margin and less than |
| or equal to the maximum upstream signal to noise margin. |
|
|