Chapter 55 Troubleshooting

The IES-612-51A is now reinitialized with a default configuration file including the default user name of “admin” and the default password of “1234”.

55.15.2 Uploading the Default Configuration File

If you forget your password or cannot access the IES-612-51A, you will need to reload the factory-default configuration file. Uploading the factory-default configuration file replaces the current configuration file with the factory-default configuration file. This means that you will lose all previous configurations and the speed of the console port will be reset to the default of 9600 bps with 8 data bit, no parity, one stop bit and flow control set to none. The password will also be reset to “1234” and the IP address to 192.168.1.1.

"Uploading the factory default configuration file erases the IES-612-51A’s entire configuration.

Obtain the default configuration file, unzip it and save it in a folder. Use a console cable to connect a computer with terminal emulation software to the IES-612-51A’s console port. Turn the IES-612-51A off and then on to begin a session. When you turn on the IES-612-51A again you will see the initial screen. When you see the message Press any key to enter Debug Mode within 3 seconds press any key to enter debug mode.

To upload the configuration file, do the following:

1Type atlc after the Enter Debug Mode message.

2Wait for the Starting XMODEM upload message before activating XMODEM upload on your terminal.

3This is an example Xmodem configuration upload using HyperTerminal. Click Transfer, then Send File to display the following screen.

Figure 296 Example Xmodem Upload

Type the configuration file's location, or click Browse to search for it. Choose the 1K Xmodem protocol. Then click Send.

4After a successful configuration file upload, type atgo to restart the IES-612-51A.

The IES-612-51A is now reinitialized with a default configuration file including the default password of “1234”.

414

 